Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin

被引:48
作者
Lim, TK [1 ]
Matsunaga, T [1 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol, Koganei, Tokyo 1848588, Japan
关键词
electrochemical flow immunoassay; Fc-IgG; miniaturized flow immunoassay system;
D O I
10.1016/S0956-5663(01)00228-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper is reported a miniaturized flow immunoassay system. Ferrocenecarboxylic acid (Fc) conjugated with anti-HCG immunoglobulin G (IgG) antibody (Fc-IgG) was prepared, and used as a novel analytical reagent. The system consists of the immunoreaction section, the capillary column packed with cation exchange resin, and the flow cell for electrochemical detection of Fc-IgG. Antibody-antigen complexes were separated from their free conjugate on the basis of differences in isoelectric point (pl) using a cation exchange capillary column. The assay yielded a linear relationship between signal and HCG concentration in the range 0-2000 mIU/ml. This simple technique enables the assay of HCG within 2 min. The cation exchange capillary column was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free conjugate. Free conjugate recovered in this manner could be reused up to eight times without significant decreases in the sensitivity of the immunoassay. This electrochemical flow immunoassay requires only minute quantities of serum and generates highly reproducible results. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1063 / 1069
页数:7
相关论文
共 31 条
[1]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[2]   DIAGNOSIS OF ECTOPIC PREGNANCY BY VAGINAL ULTRASONOGRAPHY IN COMBINATION WITH A DISCRIMINATORY SERUM HCG LEVEL OF 1000-IU/1 (IRP) [J].
CACCIATORE, B ;
STENMAN, UH ;
YLOSTALO, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (10) :904-908
[3]   Trace level detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by microimmunosensor [J].
Charles, PT ;
Kusterbeck, AW .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (04) :387-396
[4]   Accessing genetic information with high-density DNA arrays [J].
Chee, M ;
Yang, R ;
Hubbell, E ;
Berno, A ;
Huang, XC ;
Stern, D ;
Winkler, J ;
Lockhart, DJ ;
Morris, MS ;
Fodor, SPA .
SCIENCE, 1996, 274 (5287) :610-614
[5]  
CHUANLIANGA L, 1996, J CHROMATOGR B, V687, P213
[6]   Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular application of PEBBLE sensors [J].
Clark, HA ;
Kopelman, R ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4837-4843
[7]   MECHANISM OF DYE RESPONSE AND INTERFERENCE IN THE BRADFORD PROTEIN ASSAY [J].
COMPTON, SJ ;
JONES, CG .
ANALYTICAL BIOCHEMISTRY, 1985, 151 (02) :369-374
[8]   Electron transfer between ferrocene-modified Au/octadecanethiol/lipid BLM electrode and redox couples in solution [J].
Cui, XL ;
Jiang, DL ;
Diao, P ;
Li, JX ;
Tong, RT ;
Wang, XK .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1999, 48 (01) :243-247
[9]   Development of solid-phase chemiluminescence immunoassays for digoxin comparing flow injection and sequential injection techniques [J].
Dreveny, D ;
Michalowski, J ;
Seidl, R ;
Gübitz, G .
ANALYST, 1998, 123 (11) :2271-2276
[10]   LIGHT-DIRECTED, SPATIALLY ADDRESSABLE PARALLEL CHEMICAL SYNTHESIS [J].
FODOR, SPA ;
READ, JL ;
PIRRUNG, MC ;
STRYER, L ;
LU, AT ;
SOLAS, D .
SCIENCE, 1991, 251 (4995) :767-773