A plane measuring device

被引:143
作者
Criminisi, A [1 ]
Reid, I [1 ]
Zisserman, A [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 2JD, England
基金
英国工程与自然科学研究理事会;
关键词
video metrology; error analysis; projective geometry;
D O I
10.1016/S0262-8856(98)00183-8
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A requirement of a visual measurement device is that both measurements and their uncertainties can be determined. This paper develops an uncertainty analysis which includes both the errors in image localization and the uncertainty in the imaging transformation. The matrix representing the imaging transformation is estimated from image-to-world point correspondences. A,general expression is derived for the covariance of this matrix. This expression is valid if the matrix is over determined and also if the minimum number of correspondences are used. A bound on the errors of the first order approximations involved is also derived. Armed with this covariance result the uncertainty of any measurement can be predicted, and furthermore the distribution of correspondences can be chosen to achieve a particular bound on the uncertainty. Examples are given of measurements such as distance and parallelism for several applications. These include indoor scenes and architectural measurements. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:625 / 634
页数:10
相关论文
共 17 条