Quantification of the Internal Resistance Distribution of Microbial Fuel Cells

被引:468
作者
Fan, Yanzhen [1 ]
Sharbrough, Evan [1 ]
Liu, Hong [1 ]
机构
[1] Oregon State Univ, Dept Biol & Ecol Engn, Corvallis, OR 97331 USA
关键词
D O I
10.1021/es801229j
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Identifying the limiting factors in a microbial fuel cell (MFC) system requires qualifying the contribution of each component of an MFC to internal resistance. In this study, a new method was developed to calculate the internal resistance distribution of an MFC. Experiments were conducted to identify the limiting factors in single-chamber MFCs by varying the anode surface areas, cathode surface areas, and phosphate buffer concentrations. For the MFCs with equally sized electrodes (7 cm(2)) and 200 mM phosphate buffer, the anode contributed just 5.4% of the internal resistance, while the cathode and the electrolyte each contributed 47.3%, indicating that the anode was not the limiting factor in power generation. The limitation of the cathode was further revealed by the 780% higher area-specific resistance (284.4 Omega cm(2)) than the 32.3 Omega cm(2) of the anode. The electrolyte limitation was also evidenced by the greatly increased contribution of electrolyte in internal resistance from 47.3 to 78.2% when the concentration of phosphate buffer was decreased from 200 to 50 mM. An anodic power density of 6860 mW/m(2) was achieved at a current density of 2.62 mA/ cm(2) using the MFCs with an anode/cathode area ratio of 1/14 and 200 mM phosphate buffer. The method was also successfully applied to analyze the internal resistance distribution of the two chamber MFCs from a previously reported study. The comparison of the internal resistances of the two air cathode systems indicates that the much lower resistances, including anode, cathode, and membrane resistances, contributed to the much better performance of the single-chamber MFCs than the two-chamber system.
引用
收藏
页码:8101 / 8107
页数:7
相关论文
共 20 条
[1]   Continuous electricity generation at high voltages and currents using stacked microbial fuel cells [J].
Aelterman, Peter ;
Rabaey, Korneel ;
Pham, Hai The ;
Boon, Nico ;
Verstraete, Willy .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (10) :3388-3394
[2]   Public Health Genomics knowledge and attitudes: A survey of public health educators in the United States [J].
Chen, Lei-Shih ;
Goodson, Patricia .
GENETICS IN MEDICINE, 2007, 9 (08) :496-503
[3]   Increased performance of single-chamber microbial fuel cells using an improved cathode structure [J].
Cheng, S ;
Liu, H ;
Logan, BE .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (03) :489-494
[4]   Sustainable power generation in microbial fuel cells using bicarbonate buffer and proton transfer mechanisms [J].
Fan, Yanzhen ;
Hu, Hongqiang ;
Liu, Hong .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (23) :8154-8158
[5]   Enhanced Coulombic efficiency and power density of air-cathode microbial fuel cells with an improved cell configuration [J].
Fan, Yanzhen ;
Hu, Hongqiang ;
Liu, Hong .
JOURNAL OF POWER SOURCES, 2007, 171 (02) :348-354
[6]   An upflow microbial fuel cell with an interior cathode: Assessment of the internal resistance by impedance Spectroscopy [J].
He, Zhen ;
Wagner, Norbert ;
Minteer, Shelley D. ;
Angenent, Largus T. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (17) :5212-5217
[7]  
Larminie James., 2000, FUEL CELL SYSTEMS EX, DOI DOI 10.1002/9781118878330
[8]   Electricity generation using an air-cathode single chamber microbial fuel cell in the presence and absence of a proton exchange membrane [J].
Liu, H ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (14) :4040-4046
[9]   Power generation in fed-batch microbial fuel cells as a function of ionic strength, temperature, and reactor configuration [J].
Liu, H ;
Cheng, SA ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (14) :5488-5493
[10]   Graphite fiber brush anodes for increased power production in air-cathode microbial fuel cells [J].
Logan, Bruce ;
Cheng, Shaoan ;
Watson, Valerie ;
Estadt, Garett .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (09) :3341-3346