A 6-month follow-up of successful refits from daily disposable soft contact lenses to continuous wear of high-Dk silicone-hydrogel lenses

被引:30
作者
Aakre, BM
Ystenaes, AE
Doughty, MJ
Austrheim, O
Westerfjell, B
Lie, MT
机构
[1] Buskerud Univ Coll, Dept Optometry & Visual Sci, N-3603 Kongsberg, Norway
[2] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
关键词
contact lens; continuous wear; daily disposable; silicone hydrogel;
D O I
10.1111/j.1475-1313.2004.00185.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare, in routine optometric practice, the outcome of keeping successful soft contact lens (SCL) wearers in their lenses to re-fitting them with continuous wear of silicone hydrogel (SiH) lenses. Methods: Forty-nine successful daily disposable lens wearers were recruited; 19 continued to wear daily SCLs and 30 were refitted with high-Dk SiH lenses on a 30-day/night schedule. Patients were assessed at baseline, 3 and 6 months by slit lamp examination along with the Efron grading scales, and central corneal thickness (CCT) and the corneal endothelium were assessed by non-contact specular microscopy. Results: No substantial changes in subjective vision, refraction, visual acuity or overall lens comfort occurred for those completing the study, although five SiH lens wearers did discontinue due to reduced comfort, eyelid problems or seasonal allergy. Contact lens induced peripheral ulcers (CLPU) were observed in three patients in the first 3 months in the SiH lens group and these were also discontinued. Over the 6 month period, a complete set of records was obtained for 16 in each group. For those completing the study, lens dryness scores were variable, but there was a slight improvement in favour of SiH lenses. Small, but statistically significant, reductions in corneal staining, bulbar hyperaemia, and limbal neovascularisation in favour of the SiH lenses were also evident but mainly because of further increases in the daily lens wearers. Contact lens induced papillary conjunctivitis (CLPC) and corneal endothelial polymegethism were mild to moderate and showed slight increases in the daily lens wearers at 6 months. Conclusions: The present studies confirm that the continuous wear of SiH lenses for up to 30 days can be considered as an alternative to daily disposable soft lens wear, but is not suitable for everyone.
引用
收藏
页码:130 / 141
页数:12
相关论文
共 45 条
[1]   Assessment of reproducibility of measures of intraocular pressure and central corneal thickness in young white adults over a 16-h time period [J].
Aakre, BM ;
Doughty, MJ ;
Dalane, OV ;
Berg, A ;
Aamodt, O ;
Gangstad, H .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (03) :271-283
[2]  
Barr Joseph T, 2003, Eye Contact Lens, V29, P14, DOI 10.1097/00140068-200301000-00004
[3]   Characteristics of corneal staining in hydrogel contact lens wearers [J].
Begley, CG ;
Barr, JT ;
Edrington, TB ;
Long, WD ;
McKenney, CD ;
Chalmers, RL .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (03) :193-200
[4]   Responses of contact lens wearers to a dry eye survey [J].
Begley, CG ;
Caffery, B ;
Nichols, KK ;
Chalmers, R .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (01) :40-46
[5]   Morphologic changes in corneal endothelial cells during 3 years of fluorocarbon contact lens wear [J].
Bourne, WM ;
Holtan, SB ;
Hodge, DO .
CORNEA, 1999, 18 (01) :29-33
[6]   A 1-year prospective balafilcon A (pure clinical trial of vision) silicone-hydrogel contact lenses used on a 30-day continuous wear schedule [J].
Brennan, NA ;
Coles, MLC ;
Comstock, TL ;
Levy, B .
OPHTHALMOLOGY, 2002, 109 (06) :1172-1177
[7]  
Brennan Noel A, 2002, Clin Exp Optom, V85, P127
[8]   Effects of contact lenses on corneal endothelium - A morphological and functional study [J].
Chang, SW ;
Hu, FR ;
Lin, LLK .
OPHTHALMOLOGICA, 2001, 215 (03) :197-203
[9]   Hypoxic effects on the anterior eye of high-Dk soft contact lens wearers are negligible [J].
Covey, M ;
Sweeney, DF ;
Terry, R ;
Sankaridurg, PR ;
Holden, BA .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (02) :95-99
[10]   Assessment of the number of eye symptoms and the impact of some confounding variables for office staff in non-air-conditioned buildings [J].
Doughty, MJ ;
Blades, KA ;
Ibrahim, N .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (02) :143-155