Constant-height scanning is demonstrated to improve near-field microscopy by eliminating artifacts connected with topography scanning, hence, to image the inherent electromagnetic contrast. Microwaves are chosen for this study because the long wavelength eliminates coherence artifacts, owing to a scale separation of wave and image frequencies. Measured amplitude and phase images of conductive films are quantitatively analyzed by considering the longitudinal electric near field. The observed spatial resolution of 200 nm equals the probing tip size and proves that the skin depth delta of the tip material (here, 1600 nm) presents no resolution limit to scanning optical microscopy. (C) 1997 American Institute of Physics.
引用
收藏
页码:2667 / 2669
页数:3
相关论文
共 13 条
[1]   NEAR-FIELD OPTICAL MICROSCOPE BASED ON LOCAL PERTURBATION OF A DIFFRACTION SPOT [J].
BACHELOT, R ;
GLEYZES, P ;
BOCCARA, AC .
OPTICS LETTERS, 1995, 20 (18) :1924-1926
[2]   BREAKING THE DIFFRACTION BARRIER - OPTICAL MICROSCOPY ON A NANOMETRIC SCALE [J].
BETZIG, E ;
TRAUTMAN, JK ;
HARRIS, TD ;
WEINER, JS ;
KOSTELAK, RL .
SCIENCE, 1991, 251 (5000) :1468-1470
[3]   SUPERRESOLUTION FLUORESCENCE NEAR-FIELD SCANNING OPTICAL MICROSCOPY [J].
HAROOTUNIAN, A ;
BETZIG, E ;
ISAACSON, M ;
LEWIS, A .
APPLIED PHYSICS LETTERS, 1986, 49 (11) :674-676
[4]   Extreme sub-wavelength resolution with a scanning radio-frequency transmission microscope [J].
Keilmann, F ;
vanderWeide, DW ;
Eickelkamp, T ;
Merz, R ;
Stockle, D .
OPTICS COMMUNICATIONS, 1996, 129 (1-2) :15-18
[5]   IMAGING OF OPTICAL WAVETRAINS [J].
KEILMANN, F ;
KUSSMAUL, KW ;
SZENTIRMAY, Z .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1988, 47 (02) :169-176
[6]   An optical tip-sample distance control for a scanning near-field optical microscope [J].
Kramer, A ;
Hartmann, T ;
Stadler, SM ;
Guckenberger, R .
ULTRAMICROSCOPY, 1995, 61 (1-4) :191-195
[7]   The coaxial tip as a nano-antenna for scanning near-field microwave transmission microscopy [J].
Kramer, A ;
Keilmann, F ;
Knoll, B ;
Guckenberger, R .
MICRON, 1996, 27 (06) :413-417
[8]  
MARTI O, COMMUNICATION
[9]   OPTICAL STETHOSCOPY - IMAGE RECORDING WITH RESOLUTION LAMBDA/20 [J].
POHL, DW ;
DENK, W ;
LANZ, M .
APPLIED PHYSICS LETTERS, 1984, 44 (07) :651-653
[10]   SCANNING PLASMON NEAR-FIELD MICROSCOPE [J].
SPECHT, M ;
PEDARNIG, JD ;
HECKL, WM ;
HANSCH, TW .
PHYSICAL REVIEW LETTERS, 1992, 68 (04) :476-479