Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms

被引:271
作者
Nuyts, J [1 ]
Dupont, P
Stroobants, S
Benninck, R
Mortelmans, L
Suetens, P
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Louvain, Belgium
[2] Katholieke Univ Leuven, ESAT Machine Intelligence & Imaging, Louvain, Belgium
关键词
attenuation correction; maximum-likelihood reconstruction; PET; SPECT;
D O I
10.1109/42.774167
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In order to perform attenuation correction in emission tomography an attenuation map is required. We propose a new method to compute this map directly from the emission sinogram, eliminating the transmission scan from the acquisition protocol. The problem is formulated as an optimization task where the objective function is a combination of the likelihood and an a priori probability. The latter uses a Gibbs prior distribution to encourage local smoothness and a multimodal distribution for the attenuation coefficients. Since the attenuation process is different in positron emission tomography (PET) and single photon emission tomography (SPECT), a separate algorithm for each case is derived, The method has been tested on mathematical phantoms and on a few clinical studies. For PET, good agreement was found between the images obtained with transmission measurements and those produced by the new algorithm in an abdominal study. For SPECT, promising simulation results have been obtained for nonhomogeneous attenuation due to the presence of the lungs.
引用
收藏
页码:393 / 403
页数:11
相关论文
共 30 条
[11]  
Krol A., 1995, Journal of Nuclear Medicine, V36, p50P
[12]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
[13]   SIMULTANEOUS RECONSTRUCTION, SEGMENTATION, AND EDGE ENHANCEMENT OF RELATIVELY PIECEWISE CONTINUOUS IMAGES WITH INTENSITY-LEVEL INFORMATION [J].
LIANG, Z ;
JASZCZAK, R ;
COLEMAN, R ;
JOHNSON, V .
MEDICAL PHYSICS, 1991, 18 (03) :394-401
[14]  
LIANG Z, 1994, P 1993 IEEE MIC, V2, P1231
[15]  
MANGLOS SH, 1994, P 1993 IEEE MIC, P1605
[16]  
MEIKLE SR, 1993, J NUCL MED, V34, P143
[17]   ONLINE BRAIN ATTENUATION CORRECTION IN PET - TOWARDS A FULLY AUTOMATED DATA HANDLING IN A CLINICAL ENVIRONMENT [J].
MICHEL, C ;
BOL, A ;
DEVOLDER, AG ;
GOFFINET, AM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :712-718
[18]  
Moore S. C., 1997, Journal of Nuclear Medicine, V38, p68P
[19]   Bayesian reconstruction of PET images: Methodology and performance analysis [J].
Mumcuoglu, EU ;
Leahy, RM ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1777-1807
[20]   DETERMINATION OF TISSUE ATTENUATION IN EMISSION TOMOGRAPHY OF OPTICALLY DENSE MEDIA [J].
NATTERER, F .
INVERSE PROBLEMS, 1993, 9 (06) :731-736