Microvolt T-wave alternans and the risk of death or sustained ventricular arrhythmias in patients with left ventricular dysfunction

被引:212
作者
Bloomfield, DM
Bigger, JT
Steinman, RC
Namerow, PB
Parides, MK
Curtis, AB
Kaufman, ES
Davidenko, JM
Shinn, TS
Fontaine, JM
机构
[1] Columbia Univ, Med Ctr, Data Coordinating Ctr, New York, NY 10032 USA
[2] Univ S Florida, Dept Med, Tampa, FL USA
[3] Case Western Reserve Univ, Cleveland, OH 44106 USA
[4] New York Heart Ctr, Syracuse, NY USA
[5] Michigan Heart PC, Ypsilanti, MI USA
[6] Drexel Univ, Coll Med, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/j.jacc.2005.11.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study hypothesized that microvolt T-wave alternans (MTWA) improves selection of patients for implantable cardioverter-defibrillator (ICD) prophylaxis, especially by identifying patients who are not likely to benefit. BACKGROUND Many patients with left ventricular dysfunction are now eligible for prophylactic ICDs, but most eligible patients do not benefit; MTWA testing has been proposed to improve patient selection. METHODS Our study was conducted at 11 clinical centers in the U.S. Patients were eligible if they had a left ventricular ejection fraction (LVEF) <= 0.40 and lacked a history of sustained ventricular arrhythmias; patients were excluded for atrial fibrillation, unstable coronary artery disease, or New York Heart Association functional class IV heart failure. Participants underwent an MTWA test and then were followed for about two years. The primary outcome was all-cause mortality or non-fatal sustained ventricular arrhythmias. RESULTS Ischemic heart disease was present in 49%, mean LVEF was 0.25, and 66% had an abnormal MTWA test. During 20 6 months of follow-up, 51 end points (40 deaths and 11 non-fatal sustained ventricular arrhythmias) occurred. Comparing patients with normal and abnormal MTWA tests, the hazard ratio for the primary end point was 6.5 at two years (95% confidence interval 2.4 to 18.1, p < 0.001). Survival of patients with normal MTWA tests was 97.5% at two years. The strong association between MTWA and the primary end point was similar in all subgroups tested. CONCLUSIONS Among patients with heart disease and LVEF <= 0.40, MTWA can identify not only a high-risk group, but also a low-risk group unlikely to benefit from ICD prophylaxis.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 34 条
[1]  
[Anonymous], CAG00157R3 CTR MED M
[2]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[3]   Expanding indications for implantable cardiac defibrillators [J].
Bigger, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :931-933
[4]   Microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy - A solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II conundrum [J].
Bloomfield, DM ;
Steinman, RC ;
Namerow, PB ;
Parides, M ;
Davidenko, J ;
Kaufman, ES ;
Shinn, T ;
Curtis, A ;
Fontaine, J ;
Holmes, D ;
Russo, A ;
Tang, C ;
Bigger, JT .
CIRCULATION, 2004, 110 (14) :1885-1889
[5]   Interpretation and classification of microvolt T wave alternans tests [J].
Bloomfield, DM ;
Hohnloser, SH ;
Cohen, RJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) :502-512
[6]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[7]   The clinical use of implantable cardioverter defibrillators: Where are we now? Where should we go? [J].
Buxton, AE .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (06) :512-514
[8]  
Caffarone A, 2001, Ital Heart J, V2, P265
[9]   Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone [J].
Connolly, SJ ;
Gent, M ;
Roberts, RS ;
Dorian, P ;
Roy, D ;
Sheldon, RS ;
Mitchell, LB ;
Green, MS ;
Klein, GJ ;
O'Brien, B .
CIRCULATION, 2000, 101 (11) :1297-1302
[10]  
COX DR, 1972, J R STAT SOC B, V34, P187