Using the high-order finite element method, we provide accurate predictions of the friction factor and the Nusselt number for the fully developed laminar flows of power-law-type non-Newtonian fluids in rhombic, isosceles-triangular, elliptical, and semielliptical ducts. Two kinds of thermal boundary conditions, commonly referred to as the H1 and T conditions, are considered. For each type of duct, computed results are presented for several aspect ratios with the power-law index ranging from 0.2 to 1.0. Mesh refinement tests with four different meshes are carried out for two specific duct configurations, indicating that the present predictions are remarkably insensitive to mesh density.
引用
收藏
页码:89 / 100
页数:12
相关论文
共 7 条
[1]
Hartnett J. P., 1998, HDB HEAT TRANSFER
[2]
IRVINE TF, 1987, HDB SINGLE PHASE CON, pCH20
[3]
SEWELL G, 1985, ANAL FINITE ELEMENT
[4]
SEWELL G, 2000, FINITE DIFFERENCES F
[5]
Shah R. K., 1978, ADV HEAT TRANSFER S1
[6]
FINITE-ELEMENT ANALYSIS OF FULLY-DEVELOPED LAMINAR-FLOW OF POWER-LAW NON-NEWTONIAN FLUID IN A RECTANGULAR DUCT [J].
SYRJALA, S .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1995, 22 (04) :549-557
[7]
Further finite element analyses of fully developed laminar flow of power-law non-Newtonian fluid in rectangular ducts: Heat transfer predictions [J].
Syrjala, S .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1996, 23 (06) :799-807