Response of monkey glabrous skin mechanoreceptors to random noise sequences .2. Dynamic stimulus state analysis

被引:14
作者
Looft, FJ
机构
[1] Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609
基金
美国国家科学基金会;
关键词
mechanoreceptors; vibrotactile; glabrous skin; noise stimulus;
D O I
10.3109/08990229609028908
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The responses of monkey glabrous skin slowly adapting (SAI, Merkel cell), rapidly adapting (RA, Meissner) and Pacinian corpuscle (PC) mechanoreceptors were analyzed as a function of the instantaneous position, velocity, and acceleration of a dynamic stimulus. For these experiments, a vibrotactile punctate stimulator was driven by a non-repeating-noise sequence. The resulting data (sampled stimulus waveform, windowed impulse) were processed in several ways. Initially, input-output correlation analysis was implemented to generate spike-aligned averages of the stimulus waveform preceding and following impulse initiation. From this analysis, it was determined that dual-responding RA and PC afferents-that is, those afferents that responded to both indenting and extracting stimulus movements-universally responded in a nearly perfectly symmetrical manner to the stimulus. Subsequently, two-dimensional (position, velocity) state histograms were generated and used to assess mechanoreceptor dynamic stimulus sensitivities. From these state histograms, it was determined that the threshold for impulse initiation by SAI afferents was preferentially sensitive to the indentation position of the stimulus, with only a minor sensitivity to stimulus velocity. RA afferent thresholds were sensitive to a continuum of dynamic stimulus velocities and positions. At the extremes, RA afferent impulses could be initiated by either a highly indented, low-velocity stimulus or a high-velocity stimulus with a limited indentation position. PC afferents appeared to be preferentially sensitive to a combination of stimulus velocity and acceleration, but the data-sampling interval was too coarse to adequately resolve the full range of dynamic stimulus sensitivities.
引用
收藏
页码:11 / 28
页数:18
相关论文
共 26 条
[1]   THE RELATIONSHIP BETWEEN A NEURONAL CROSS-CORRELOGRAM AND THE UNDERLYING POSTSYNAPTIC CURRENT [J].
AWISZUS, F .
BIOLOGICAL CYBERNETICS, 1992, 67 (03) :279-283
[2]   THE STRUCTURE AND FUNCTION OF PACINIAN CORPUSCLES - A REVIEW [J].
BELL, J ;
BOLANOWSKI, S ;
HOLMES, MH .
PROGRESS IN NEUROBIOLOGY, 1994, 42 (01) :79-128
[3]   INTENSITY AND FREQUENCY-CHARACTERISTICS OF PACINIAN CORPUSCLES .2. RECEPTOR POTENTIALS [J].
BOLANOWSKI, SJ ;
ZWISLOCKI, JJ .
JOURNAL OF NEUROPHYSIOLOGY, 1984, 51 (04) :812-830
[4]   INTENSITY AND FREQUENCY-CHARACTERISTICS OF PACINIAN CORPUSCLES .1. ACTION-POTENTIALS [J].
BOLANOWSKI, SJ ;
ZWISLOCKI, JJ .
JOURNAL OF NEUROPHYSIOLOGY, 1984, 51 (04) :793-811
[5]  
COHEN RH, 1993, EXP BRAIN RES, V94, P105
[6]   CUTANEOUS MECHANORECEPTORS IN MACAQUE MONKEY - TEMPORAL DISCHARGE PATTERNS EVOKED BY VIBRATION, AND A RECEPTOR MODEL [J].
FREEMAN, AW ;
JOHNSON, KO .
JOURNAL OF PHYSIOLOGY-LONDON, 1982, 323 (FEB) :21-41
[7]   A MODEL ACCOUNTING FOR EFFECTS OF VIBRATORY AMPLITUDE ON RESPONSES OF CUTANEOUS MECHANORECEPTORS IN MACAQUE MONKEY [J].
FREEMAN, AW ;
JOHNSON, KO .
JOURNAL OF PHYSIOLOGY-LONDON, 1982, 323 (FEB) :43-64
[8]  
GOODWIN AW, 1989, EXP BRAIN RES, V77, P79
[9]   RESPONSES TO THRESHOLD AND SUPRATHRESHOLD STIMULI BY SLOWLY ADAPTING CUTANEOUS MECHANORECEPTORS IN CAT [J].
HORCH, KW ;
BURGESS, PR .
JOURNAL OF COMPARATIVE PHYSIOLOGY, 1976, 110 (03) :307-315
[10]  
IGGO A, 1985, REV NEUROL, V141, P599