Stereotactic CT-guided percutaneous stabilization of posterior pelvic ring fractures: A preclinical cadaver study

被引:24
作者
Bale, Reto J. [2 ]
Kovacs, Peter [2 ]
Dolati, Bahman [1 ]
Hinterleithner, Christoph [2 ]
Rosenberger, Ralf E. [1 ]
机构
[1] Med Univ Innsbruck, Dept Trauma Surg, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Radiol, Interdisciplinary Stereotact Intervent & Planning, A-6020 Innsbruck, Austria
关键词
D O I
10.1016/j.jvir.2008.04.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To determine the accuracy of frameless stereotactic computed tomographic (CT)-guided wire placement for percutaneous fixation of posterior pelvic ring fractures in human cadavers. MATERIALS AND METHODS: Four intact human cadavers were fixated in a double-vacuum immobilization system. A 2.5-mm helical CT dataset was obtained and transferred to the three-dimensional (3D) navigation system. In every specimen, two paths on each side (total number, 16) were defined on multiplanar reconstructions of the 3D CT datasets, simulating fixation of the iliosacral joint. An aiming device was adjusted according to the plan, and a 2.5-mm pin was advanced through the aiming device to the precalculated target point. To determine the accuracy of pin placement, a control CT scan was co-registered to the planning CT scan (with the planned trajectories). The distance between the planned and achieved positions of the pins (3D accuracy) was calculated in millimeters. RESULTS: The mean 3D accuracy was 1.84 mm +/- 0.9 (standard deviation) at the bone entrance point and 2.5 mm +/- 1.2 at the target, as determined with image fusion between the planning CT scan and the control CT scan with the pins in place. CONCLUSIONS: The described technique enables accurate placement of pins in the pelvis and may be useful for percutaneous orthopedic procedures.
引用
收藏
页码:1093 / 1098
页数:6
相关论文
共 37 条
[1]
Superior gluteal artery injury during iliosacral screw placement [J].
Altman, DT ;
Jones, CB ;
Routt, MLC .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (03) :220-222
[2]
Computer-guidance in percutaneous screw stabilization of the iliosacral joint [J].
Arand, M ;
Kinzl, L ;
Gebhard, F .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (422) :201-207
[3]
A novel vacuum device for extremity immobilisation during digital angiography: preliminary clinical experiences [J].
Bale, RJ ;
Lottersberger, C ;
Vogele, M ;
Prassl, A ;
Czermak, B ;
Dessl, A ;
Sweeney, RA ;
Waldenberger, P ;
Jaschke, W .
EUROPEAN RADIOLOGY, 2002, 12 (12) :2890-2894
[4]
Osteochondral lesions of the talus: Computer-assisted retrograde drilling - Feasibility and accurracy in initial experiences [J].
Bale, RJ ;
Hoser, C ;
Rosenberger, R ;
Rieger, M ;
Benedetto, KP ;
Fink, C .
RADIOLOGY, 2001, 218 (01) :278-282
[5]
Burtscher J, 2003, MINIM INVAS NEUROSUR, V46, P208
[6]
Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws - A cadaver model [J].
Collinge, C ;
Coons, D ;
Tornetta, P ;
Aschenbrenner, J .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (04) :254-258
[7]
Risks to the superior gluteal neurovascular bundle during percutaneous iliosacral screw insertion - An anatomical cadaver study [J].
Collinge, C ;
Coons, D ;
Aschenbrenner, J .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (02) :96-101
[8]
Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures [J].
Comstock, CP ;
vanderMeulen, MCH ;
Goodman, SB .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) :517-522
[9]
Dorward N L, 1997, Comput Aided Surg, V2, P180, DOI 10.1002/(SICI)1097-0150(1997)2:3/4<180::AID-IGS5>3.0.CO
[10]
2-V