Comparison of saliva and serum for human immunodeficiency virus type 1 antibody testing in uganda using a rapid recombinant assay

被引:13
作者
Grant, RM
Piwowar, EM
KatongoleMbidde, E
Muzawalu, W
Rugera, S
Abima, J
Stramer, SL
Kataaha, P
Jackson, B
机构
[1] UNIV CALIF SAN FRANCISCO,SAN FRANCISCO,CA 94143
[2] UNIV HOSP CLEVELAND,CLEVELAND,OH 44106
[3] CASE WESTERN RESERVE UNIV,CLEVELAND,OH 44106
[4] ABBOTT LABS,ABBOTT PK,IL 60064
[5] UGANDA CANC INST,IMMUNOL LAB,KAMPALA,UGANDA
[6] NAKASERO BLOOD BANK,KAMPALA,UGANDA
[7] UGANDA MINIST HLTH,KAMPALA,UGANDA
[8] MAKERERE UNIV,SCH MED,DEPT MICROBIOL,KAMPALA,UGANDA
关键词
D O I
10.1128/CDLI.3.6.640-644.1996
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The accuracy and acceptability of saliva human immunodeficiency virus type 1 (HIV-1) antibody testing were compared with serum testing in a study of paired specimens from HIV-1-seropositive and HIV-1-seronegative Ugandan adults attending a clinic for sexually transmitted diseases. Saliva collection was performed with the Omni-sal device (Saliva Diagnostic Systems, Vancouver, Wash.), and antibody testing was performed by a rapid filter paper essay (Test-Pack; Abbott Laboratories, Abbott Park, Ill.). Relative to serum testing, the sensitivity of saliva testing was 95% (195 of 205) and the specificity was 99% (295 of 297). The sensitivity of saliva testing was higher for patients with elevated levels of beta-2 microglobulin in sera and greater numbers of HIV-1-related symptoms. Pre- and poststudy interviews indicated that saliva testing did not foster inordinate fears of saliva exposure, The development of saliva tests that are inexpensive and do not require electricity is needed.
引用
收藏
页码:640 / 644
页数:5
相关论文
共 18 条
[1]  
BARRIGA G, 1992, pB191
[2]  
BEHETS FM, 1991, J ACQ IMMUN DEF SYND, V4, P183
[3]   IMMUNIZATION AND FEAR OF AIDS [J].
BERKLEY, S ;
WEEKS, M ;
BARENZI, J .
LANCET, 1990, 335 (8680) :47-48
[4]   COMPARISON OF 8 COMMERCIAL TEST KITS FOR DETECTING ANTI-HIV ANTIBODIES IN SALIVA SPECIMENS [J].
CHAMNANPUT, J ;
PHANUPHAK, P .
AIDS, 1993, 7 (07) :1026-1026
[5]   NOVEL ASSAY FOR THE DETECTION OF IMMUNOGLOBULIN-G ANTIHUMAN IMMUNODEFICIENCY VIRUS IN UNTREATED SALIVA AND URINE [J].
CONNELL, JA ;
PARRY, JV ;
MORTIMER, PP ;
DUNCAN, J .
JOURNAL OF MEDICAL VIROLOGY, 1993, 41 (02) :159-164
[6]   COMPARISON OF SALIVA AND SERUM FOR HIV SURVEILLANCE IN DEVELOPING-COUNTRIES [J].
FRERICHS, RR ;
HTOON, MT ;
ESKES, N ;
LWIN, S .
LANCET, 1992, 340 (8834-5) :1496-1499
[7]   SALIVA-BASED HIV-ANTIBODY TESTING IN THAILAND [J].
FRERICHS, RR ;
SILARUG, N ;
ESKES, N ;
PAGCHAROENPOL, P ;
RODKLAI, A ;
THANGSUPACHAI, S ;
WONGBA, C .
AIDS, 1994, 8 (07) :885-894
[8]  
GRANT R M, 1992, pC248
[9]   HIV ANTIBODIES IN WHOLE SALIVA DETECTED BY ELISA AND WESTERN-BLOT ASSAYS [J].
HOLMSTROM, P ;
SYRJANEN, S ;
LAINE, P ;
VALLE, SL ;
SUNI, J .
JOURNAL OF MEDICAL VIROLOGY, 1990, 30 (04) :245-248
[10]  
LEHNER T, 1992, IMMUNOLOGY ORAL DIS, P12