Osteocytes and bone lining cells: Which are the best candidates for mechano-sensors in cancellous bone?

被引:91
作者
Mullender, MG [1 ]
Huiskes, R [1 ]
机构
[1] UNIV NIJMEGEN,INST ORTHOPAED,BIOMECH SECT,NL-6500 HB NIJMEGEN,NETHERLANDS
关键词
trabecular bone; bone remodeling; mechano-sensory system; osteocyte; bone lining cell; computer simulation;
D O I
10.1016/S8756-3282(97)00036-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previously, we have investigated the possible role of osteocytes as mechano-sensors, and mediators of bone turnover, It was found that the proposed regulatory mechanism produced morphologies of trabecular bone, under particular loading conditions, which were consistent with morphogenesis and adaptation as seen in reality, The main objective of this study was to discern whether lining cells or osteoblasts could possibly play a similar role as effectively with regard to their capacity for self-optimization of the trabecular architecture, in terms of a low apparent mass to stiffness ratio, For that purpose the earlier analyses with osteocytes as mechano-sensors, distributed throughout the bone, were repeated for mechano-sensors located at bone surfaces only, Compared to the osteocyte model, the surface cell remodeling algorithm was reluctant to change its architecture, which implies that it is less sensitive to changes in the loading pattern, This resulted in less efficient bone adaptation, which was reflected by a considerably higher relative mass for a similar apparent stiffness in the loading direction, In other words, more mass is needed to obtain an equally stiff structure, at the apparent level, with respect to the externally applied loads, Furthermore, stresses and strains at the tissue level vary across a much wider range, relative to the osteocyte model, where the higher incidence of elevated strains indicates an increased failure risk, Therefore, we conclude that mechanical information at the bone surface may not be sufficient to adequately regulate functional bone adaptation. (C) 1997 by Elsevier Science Inc.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 25 条
[1]  
Burger E.H., 1993, BONE, V7, P37
[2]   CANDIDATES FOR THE MECHANOSENSORY SYSTEM IN BONE [J].
COWIN, SC ;
MOSSSALENTIJN, L ;
MOSS, ML .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (02) :191-197
[4]  
ELHAJ AJ, 1990, J BONE MINER RES, V5, P923
[5]   BONE STRAIN SENSATION VIA TRANSMEMBRANE POTENTIAL CHANGES IN SURFACE OSTEOBLASTS - LOADING RATE AND MICROSTRUCTURAL IMPLICATIONS [J].
HARRIGAN, TP ;
HAMILTON, JJ .
JOURNAL OF BIOMECHANICS, 1993, 26 (02) :183-200
[6]  
HOLLISTER SJ, 1992, RECENT ADVANCES IN COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING, P308
[7]  
Jacobs C.R., 1994, Proceedings of the ASME Bioengineering Conference, VBED-28, P147
[8]   SENSITIVITY OF OSTEOCYTES TO BIOMECHANICAL STRESS IN-VITRO [J].
KLEINNULEND, J ;
VANDERPLAS, A ;
SEMEINS, CM ;
AJUBI, NE ;
FRANGOS, JA ;
NIJWEIDE, PJ ;
BURGER, EH .
FASEB JOURNAL, 1995, 9 (05) :441-445
[9]   OSTEOCYTES, STRAIN DETECTION, BONE MODELING AND REMODELING [J].
LANYON, LE ;
RUBIN ;
RAISZ ;
MAROTTI ;
LEES .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 :S102-S107
[10]  
LUO G, 1995, BONE STRUCTURE REMOD, P189