Microchip technology for automated and parallel patch-clamp recording

被引:2
作者
Brueggemann, Andrea
Stoelzle, Sonja
George, Michael
Behrends, Jan C.
Fertig, Niels
机构
[1] Nanion Technol GmbH, D-80336 Munich, Germany
[2] Univ Freiburg, Dept Physiol, D-79104 Freiburg, Germany
关键词
biomedicine; cells; drug development; high-throughput screening; ion channels;
D O I
10.1002/smll.200600083
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The patch-clamp technique is the state-of-the-art technology for the study of a large class of membrane proteins called ion channels. Ion channels mediate electrical current flow, have crucial roles in cellular physiology, and are important drug targets. However, patch clamping is a laborious process requiring a skilled experimenter and is, therefore, not compatible with the high throughput needed in drug development. The solution for automated and parallel patch-clamp measurements that is provided by microchip technology is presented here.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 18 条
[1]  
[Anonymous], 1992, Ionic Channels of Excitable Membranes Sunderland
[2]  
Ashcroft F.M., 2000, Ion Channels and Disease
[3]   Activity of single ion channel proteins detected with a planar microstructure [J].
Fertig, N ;
Klau, M ;
George, M ;
Blick, RH ;
Behrends, JC .
APPLIED PHYSICS LETTERS, 2002, 81 (25) :4865-4867
[4]   Whole cell patch clamp recording performed on a planar glass chip [J].
Fertig, N ;
Blick, RH ;
Behrends, JC .
BIOPHYSICAL JOURNAL, 2002, 82 (06) :3056-3062
[5]   IMPROVED PATCH-CLAMP TECHNIQUES FOR HIGH-RESOLUTION CURRENT RECORDING FROM CELLS AND CELL-FREE MEMBRANE PATCHES [J].
HAMILL, OP ;
MARTY, A ;
NEHER, E ;
SAKMANN, B ;
SIGWORTH, FJ .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1981, 391 (02) :85-100
[6]   Mammalian electrophysiology on a microfluidic platform [J].
Ionescu-Zanetti, C ;
Shaw, RM ;
Seo, JG ;
Jan, YN ;
Jan, LY ;
Lee, LP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (26) :9112-9117
[7]   An air-molding technique for fabricating PDMS planar patch-clamp electrodes [J].
Klemic, KG ;
Klemic, JF ;
Sigworth, FJ .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2005, 449 (06) :564-572
[8]   Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells [J].
Klemic, KG ;
Klemic, JF ;
Reed, MA ;
Sigworth, FJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :597-604
[9]   Realization of hollow SiO2 micronozzles for electrical measurements on living cells [J].
Lehnert, T ;
Gijs, MAM ;
Netzer, R ;
Bischoff, U .
APPLIED PHYSICS LETTERS, 2002, 81 (26) :5063-5065
[10]   SINGLE-CHANNEL CURRENTS RECORDED FROM MEMBRANE OF DENERVATED FROG MUSCLE-FIBERS [J].
NEHER, E ;
SAKMANN, B .
NATURE, 1976, 260 (5554) :799-802