Stent-graft design: the good, the bad and the ugly

被引:54
作者
Chuter, TAM [1 ]
机构
[1] Univ Calif San Francisco, Div Vasc Surg, San Francisco, CA 94143 USA
来源
CARDIOVASCULAR SURGERY | 2002年 / 10卷 / 01期
关键词
aneurysm; aorta; endovascular repair; stent-graft;
D O I
10.1016/S0967-2109(01)00120-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
10 years of experience with endovascular AAA repair has yielded important information regarding the relationship between stent-graft design and stent-graft performance. Commercially available systems differ in important ways. General conclusions regarding endovascular AAA repair need to be qualified by reference to a specific system, or systems. Nevertheless, one can draw conclusions regarding the observed effects of certain design features, some of which are common to several devices. For example: tapered, trackable delivery systems (less than or equal to20 French in diameter) rarely fail to traverse tortuous iliac arteries: transmural barbs provide the most secure means of proximal attachment, column strength is of little value; proximal stent migration is becoming the primary late failure mode; modular stent-grafts are more versatile than unibody stent-grafts; fully-stented graft limbs are less prone to thrombosis than unstented graft limbs, iliac implantation and low porosity are associated with lower rates of aneurysm dilatation in the absence of endoleak (endotension); any movement between the angle of a stent and the overlying fabric will lead to grafts erosion; unpolished (black) Nitinol is prone to fracture; and a long trunk/short limb combination is more stable than a short trunk/long limb combination. (C) 2002 The International Society for Cardiovascular Surgery. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 35 条
  • [1] Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms
    Albertini, JN
    Kalliafas, S
    Travis, S
    Yusuf, SW
    Macierewicz, JA
    Whitaker, SC
    Elmarasy, NM
    Hopkinson, BR
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (03) : 308 - 312
  • [2] Anderson JL, 2001, J ENDOVASC THER, V8, P3, DOI 10.1583/1545-1550(2001)008<0003:EAGWRA>2.0.CO
  • [3] 2
  • [4] Common iliac artery aneurysms in patients with abdominal aortic aneurysms
    Armon, MP
    Wenham, PW
    Whitaker, SC
    Gregson, RHS
    Hopkinson, BR
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 255 - 257
  • [5] Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms
    Baum, RA
    Carpenter, RP
    Cope, C
    Golden, MA
    Velazquez, OC
    Neschis, DG
    Mitchell, ME
    Barker, CF
    Fairman, RM
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (01) : 32 - 40
  • [6] Beebe HG, 2001, J VASC SURG, V33, pS55
  • [7] Transrenal fixation of aortic stent-grafts for the treatment of infrarenal aortic aneurysmal disease
    Bove, PG
    Long, GW
    Zelenock, GB
    Bendick, PJ
    Khoury, MD
    Burr, MO
    Bechtel, G
    Becker, F
    Huckabone, C
    [J]. JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) : 697 - 702
  • [8] Endovascular repair of abdominal aortic aneurysm: Getting out of trouble
    Chuter, TAM
    Reilly, LM
    Kerlan, RK
    Sawhney, R
    Canto, CJ
    Ring, EJ
    Messina, LM
    [J]. CARDIOVASCULAR SURGERY, 1998, 6 (03): : 232 - 239
  • [9] Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair
    Chuter, TAM
    Risberg, B
    Hopkinson, BR
    Wendt, G
    Scott, RAP
    Walker, PJ
    Viscomi, S
    White, G
    [J]. JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) : 655 - 666
  • [10] Chuter TAM, 2001, J ENDOVASC THER, V8, P25, DOI 10.1583/1545-1550(2001)008<0025:AESFTA>2.0.CO