Needle biopsy in the NHS Breast Screening Programme 1996/97: how much and how accurate?

被引:29
作者
Britton, PD
McCann, J
机构
[1] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Dept Community Med, Strangeways Res Lab, Cambridge, England
关键词
D O I
10.1016/S0960-9776(99)90330-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We have shown that 62% of cancers detected in the National Health Service Breast Screening Programme are diagnosed preoperatively by needle biopsy. Although still short of the 70% national target there is a year on year improvement in the pre-operative diagnosis rate and further increases should be achievable with greater experience. The numbers of core biopsies being performed is increasing although fine needle aspiration cytology remains the mainstay biopsy technique in the UK, Core biopsy (CB) shows distinct advantages over fine needle aspiration cytology in terms of absolute ability to diagnose malignancy and benignity. There is also a much lower inadequate rate with CB. Importantly, however, we have found that the false negative rate is higher with CB, Various reasons have been advanced to explain this and with greater experience and close attention to biopsy technique this level of false negatives may fall. These data emphasize that, whichever needle biopsy technique is used, the results should not be interpreted in isolation but considered in conjunction with clinical and radiological findings for best and safest practice.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 12 条
[1]   Stereotactic core-needle biopsy of the breast: A report of the joint task force of the American College of Radiology, American College of Surgeons, and College of American Pathologists [J].
Bassett, L ;
Winchester, DP ;
Caplan, RB ;
Dershaw, DD ;
Dowlatshahi, K ;
Evans, WP ;
Fajardo, LL ;
Fitzgibbons, PL ;
Henson, DE ;
Hutter, RVP ;
Morrow, M ;
Paquelet, JR ;
Singletary, SE ;
Curry, J ;
WilcoxBuchalla, P ;
Zinninger, M .
CA-A CANCER JOURNAL FOR CLINICIANS, 1997, 47 (03) :171-+
[2]  
*BREAST SCREEN REV, 1997, NHSBSP PUBL, V97
[3]   Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy [J].
Brenner, RJ ;
Fajardo, L ;
Fisher, PR ;
Dershaw, DD ;
Evans, WP ;
Bassett, L ;
Feig, S ;
Mendelson, E ;
Jackson, V ;
Margolin, FR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :341-346
[4]   Fine needle aspiration or core biopsy [J].
Britton, PD .
BREAST, 1999, 8 (01) :1-4
[5]   Changing to core biopsy in an NHS breast screening unit [J].
Britton, PD ;
Flower, CDR ;
Freeman, AH ;
Sinnatamby, R ;
Warren, R ;
Goddard, MJ ;
Wight, DGD ;
Bobrow, L .
CLINICAL RADIOLOGY, 1997, 52 (10) :764-767
[6]  
Forrest S. P., 1986, BREAST CANC SCREENIN
[7]   STEREOTAXIC 14-GAUGE BREAST BIOPSY - HOW MANY CORE BIOPSY SPECIMENS ARE NEEDED [J].
LIBERMAN, L ;
DERSHAW, DD ;
ROSEN, PP ;
ABRAMSON, AF ;
DEUTCH, BM ;
HANN, LE .
RADIOLOGY, 1994, 192 (03) :793-795
[8]   The impact of core-biopsy on pre-operative diagnosis rate of screen detected breast cancers [J].
Litherland, JC ;
Evans, AJ ;
Wilson, ARM ;
Kollias, J ;
Pinder, SE ;
Elston, CW ;
Ellis, IO ;
Yeoman, LJ .
CLINICAL RADIOLOGY, 1996, 51 (08) :562-565
[9]   AUTOMATED LARGE-CORE NEEDLE-BIOPSY OF SURGICALLY REMOVED BREAST-LESIONS - COMPARISON OF SAMPLES OBTAINED WITH 14-GAUGE, 16-GAUGE, AND 18-GAUGE NEEDLES [J].
NATH, ME ;
ROBINSON, TM ;
TOBON, H ;
CHOUGH, DM ;
SUMKIN, JH .
RADIOLOGY, 1995, 197 (03) :739-742
[10]   A practical approach to minimally invasive breast biopsy [J].
Parker, SH ;
Burbank, F .
RADIOLOGY, 1996, 200 (01) :11-20