MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence

被引:117
作者
Hatabu, H [1 ]
Gaa, J [1 ]
Tadamura, E [1 ]
Edinburgh, KJ [1 ]
Stock, KW [1 ]
Garpestad, E [1 ]
Edelman, RR [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol & Med, Boston, MA 02215 USA
关键词
magnetic resonance imaging; pulmonary parenchyma; half-Fourier single-shot turbo spin echo;
D O I
10.1016/S0720-048X(98)00167-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the utility of a half-Fourier single-shot turbo spin-echo sequence (HASTE) at depicting lung parenchyma and lung pathology. Methods and patients: A HASTE sequence was applied to five normal volunteers and 20 patients with various pulmonary disorders to depict the lung parenchyma. Images were acquired with EGG-triggering and breath-holding. In three volunteers, signal intensity measurements from lung parenchyma were performed using four sequences: (a) HASTE; (b) conventional spin echo; (c) hat spin echo: and (d) gradient echo. T2 maps were produced using the HASTE acquisition. Results: Minimal respiratory or cardiac motion artifacts were observed. The signal-to-noise ratios from lung parenchyma were 27.8 +/- 5.4, 22.0 +/- 3.0, 15.3 +/- 0.9, and 6.0 +/- 1.9 for HASTE, spin-echo, fast spin-echo, and gradient echo sequences, respectively. The scan time for HASTE was 302 ms for each slice. The T2 values in the right lung and the left lung were 61.2 +/- 4.1 and 79.1 +/- 8.9 ms in systole and 92.6 +/- 5.8 and 97.5 +/- 12.2 ms in diastole, respectively (P < 0.05 diastole versus systole). The HASTE sequence demonstrated clearly various pulmonary disorders, including lung cancer, hilar lymphadenopathy, metastatic pulmonary nodules as small as 3 mm, pulmonary hemorrhage, pulmonary edema and bronchial wall thickening in bronchiectasis. Conclusion: Our preliminary results indicate that the HASTE sequence provides a practical means for breath-hold MR imaging of lung parenchyma. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 37 条
  • [1] AILION DC, 1984, B MAGN RESON, V6, P130
  • [2] MULTISLICE, BREATHHOLD IMAGING OF THE LUNG WITH SUBMILLISECOND ECHO TIMES
    ALSOP, DC
    HATABU, H
    BONNET, M
    LISTERUD, J
    GEFTER, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 678 - 682
  • [3] MAGNETIC-RESONANCE-IMAGING OF LUNG PARENCHYMA
    BERGIN, CJ
    GLOVER, GM
    PAULY, J
    [J]. JOURNAL OF THORACIC IMAGING, 1993, 8 (01) : 12 - 17
  • [4] LUNG PARENCHYMA - MAGNETIC-SUSCEPTIBILITY IN MR IMAGING
    BERGIN, CJ
    GLOVER, GH
    PAULY, JM
    [J]. RADIOLOGY, 1991, 180 (03) : 845 - 848
  • [5] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [6] MR IMAGING OF LOW SIGNAL INTENSITY PULMONARY-LESIONS USING FLOW-SENSITIVE TECHNIQUES
    BROWN, JJ
    GILBERT, T
    GAMSU, G
    GOLDEN, JA
    HIGGINS, CB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (04) : 560 - 564
  • [7] MR DIAGNOSIS OF LIPOID PNEUMONIA
    CARRILLON, Y
    TIXIER, E
    REVEL, D
    CORDIER, JF
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (05) : 876 - 877
  • [8] A MATHEMATICAL-MODEL OF DIAMAGNETIC LINE BROADENING IN LUNG-TISSUE AND SIMILAR HETEROGENEOUS SYSTEMS - CALCULATIONS AND MEASUREMENTS
    CASE, TA
    DURNEY, CH
    AILION, DC
    CUTILLO, AG
    MORRIS, AH
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (02): : 304 - 314
  • [9] ALVEOLAR AIR-TISSUE INTERFACE AND NUCLEAR-MAGNETIC-RESONANCE BEHAVIOR OF LUNG
    CUTILLO, AG
    GANESAN, K
    AILION, DC
    MORRIS, AH
    DURNEY, CH
    SYMKO, SC
    CHRISTMAN, RA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (05) : 2145 - 2154
  • [10] PULMONARY ARTERIOVENOUS-MALFORMATIONS - DIAGNOSIS BY GRADIENT-REFOCUSED MR IMAGING
    DINSMORE, BJ
    GEFTER, WB
    HATABU, H
    KRESSEL, HY
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 918 - 923