Effect of water on the oxygen barrier properties of poly(ethylene terephthalate) and polylactide films

被引:141
作者
Auras, R [1 ]
Harte, B [1 ]
Selke, S [1 ]
机构
[1] Michigan State Univ, Sch Packaging, E Lansing, MI 48824 USA
关键词
diffusion; barrier; biodegradable; films;
D O I
10.1002/app.20148
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The aim of this work was to study the variations in the oxygen diffusion, solubility, and permeability coefficients of polylactide (PLA) films at different temperatures (5, 23, and 40degreesC) and water activities (0-0.9). The results were compared with the oxygen diffusion, solubility, and permeability coefficients obtained for poly(ethylene terephthalate) (PET) films under the same experimental conditions. The water sorption isotherm for PLA films was also determined. Diffusion coefficients were determined with the half-sorption time method. Also, a consistency test for continuous-flow permeability experimental data was run to obtain the diffusion coefficient with the lowest experimental error and to confirm that oxygen underwent Fickian diffusion in the PLA films. The permeability coefficients were obtained from steady-state permeability experiments. The results indicated that the PLA films absorbed very low amounts of water, and no significant variation of the absorbed water with the temperature was found. The oxygen permeability coefficients obtained for PLA films (2-12 x 10(-18) kg m/m(2) s Pa) were higher than those obtained for PET films (1-6 X 10(-18) kg m/m(2) s Pa) at different temperatures and water activities. Moreover, the permeability coefficients for PLA and PET films did not change significantly with changes in the water activity at temperatures lower than 23degreesC. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:1790 / 1803
页数:14
相关论文
共 52 条
  • [1] [Anonymous], 2000, PLASTICS PACKAGING
  • [2] AURAS R, 2003, ANN TECH C P, V3, P2862
  • [3] AURAS R, 2002, P WORLDP 2002 E LANS, P1011
  • [4] BAILLIE J, 1997, PACKAG WEEK, V13, P13
  • [5] Barr CD, 2000, PACKAG TECHNOL SCI, V13, P157, DOI 10.1002/1099-1522(200007)13:4<157::AID-PTS506>3.0.CO
  • [6] 2-L
  • [7] POLYMERS FOR ABSORBABLE SURGICAL SUTURES .1.
    BENICEWICZ, BC
    HOPPER, PK
    [J]. JOURNAL OF BIOACTIVE AND COMPATIBLE POLYMERS, 1990, 5 (04) : 453 - 472
  • [8] Effect of filler type on the mechanical properties of self-reinforced polylactide-calcium phosphate composites
    Bleach, NC
    Tanner, KE
    Kellomäki, M
    Törmälä, P
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) : 911 - 915
  • [9] Chapra SC., 1998, NUMERICAL METHODS EN
  • [10] SAFETY ASSESSMENT OF POLYLACTIDE (PLA) FOR USE AS A FOOD-CONTACT POLYMER
    CONN, RE
    KOLSTAD, JJ
    BORZELLECA, JF
    DIXLER, DS
    FILER, LJ
    LADU, BN
    PARIZA, MW
    [J]. FOOD AND CHEMICAL TOXICOLOGY, 1995, 33 (04) : 273 - 283