Evaluation of high-performance liquid chromatography column retentivity using macromolecular probes I

被引:14
作者
Berek, D [1 ]
机构
[1] Slovak Acad Sci, Inst Polymer, Lab Liquid Chromatog, Bratislava 84236, Slovakia
关键词
stationary phases; LC; macromolecular probes; column retentivity; polystyrene; poly(methyl methacrylate);
D O I
10.1016/S0021-9673(02)00061-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of macromolecular probes is proposed for evaluation of HPLC column retentivity. The idea is tested with a set of different commercial silica C-18 reversed-phases. For comparison, porous glass C-18 and polystyrene/divinylbenzene column packings are also included. Polar, mainly silanophilic interactions are evaluated. The retention volumes of a series of narrow molar mass distribution polystyrenes (PS) and poly(methyl methacrylate)s (PMMA) in toluene eluent are compared. Toluene is a weak mobile phase concerning silica gel surface and it promotes adsorption of PMMA on silanols, while PS is not adsorbed from toluene. Simultaneously, toluene is a thermodynamically good solvent for both polymers so that extensive partition in favour of stationary phase is not probable. Differences in retention behaviour of PS and PMMA indicate presence of abundant free silanols on the surface of some reversed-phases. These silanols are accessible even for large macromolecules of PMMA. Pore diameter and pore volume of the column packing can be semiquantitatively evaluated from the elution data of PS in toluene in the course of retentivity tests. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 18 条
[1]  
Belenkii BG, 1996, ACS SYM SER, V635, P274
[2]   SEPARATION OF POLY(METHYL METHACRYLATE)S ACCORDING TO THEIR TACTICITY .1. PRELIMINARY STUDIES ON THE TACTICITY DEPENDENCE OF CHROMATOGRAPHIC BEHAVIOR OF STEREOREGULAR PMMAS [J].
BEREK, D ;
JANCO, M ;
KITAYAMA, T ;
HATADA, K .
POLYMER BULLETIN, 1994, 32 (5-6) :629-635
[3]  
BEREK D, 1975, MAKROMOL CHEM, V176, P391
[4]  
BEREK D, 2000, P WAT INT S GEL PERM
[5]  
Berek D., 1999, COLUMN HDB SIZE EXCL, P445
[6]  
Buszewski B, 1998, HRC-J HIGH RES CHROM, V21, P267
[7]   Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography [J].
Claessens, HA ;
van Straten, MA ;
Cramers, CA ;
Jezierska, M ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :135-156
[8]  
CLAESSENS HA, IN PRESS TRENDS ANAL
[9]  
Euerby MR, 2000, LC GC EUR, V13, P665
[10]   A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY [J].
GRUBISIC, Z ;
REMPP, P ;
BENOIT, H .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER LETTERS, 1967, 5 (9PB) :753-&