Picodroplet-deposition of enzymes on functionalized self-assembled monolayers as a basis for miniaturized multi-sensor structures

被引:27
作者
Mosbach, M
Zimmermann, H
Laurell, T
Nilsson, J
Csöregi, E
Schuhmann, W
机构
[1] Ruhr Univ Bochum, D-44780 Bochum, Germany
[2] Lund Inst Technol, Dept Elect Measurement, SE-22100 Lund, Sweden
[3] Lund Univ, Dept Biotechnol, SE-22100 Lund, Sweden
关键词
microdispenser; microstructure; enzymes; scanning electrochemical microscopy;
D O I
10.1016/S0956-5663(01)00205-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We are reporting on a novel approach for structured immobilisation of enzymes on gold surfaces modified with monolayers of functionalised alkylthiols. The formation of enzyme spots is achieved by shooting very small volumes of an appropriate enzyme solution (down to 100 pl) onto a thiol-monolayer modified gold surface using a micro-dispenser. Formation of enzyme patterns is obtained by moving the micro-dispenser relative to the modified gold surface using a micro-positioning device. Enzyme spots with typical lateral dimensions of 100 ml are obtained, but also, more complex structures, e.g. lines or meander structures, can be achieved by multiple droplets dispensed during the concomitant movement of the micro-dispenser. The first enzyme layer on top of the functionalised thiol-monolayer is subsequently covalently immobilised using either carbodiimide activation of carboxilic headgroups at the enzyme or via already introduced activated ester functions at the monolayer. Immobilised enzyme activities of glucose oxidase and lactate oxidase patterns have been characterised by means of scanning electrochemical microscopy. The product of the enzyme-catalysed reaction, H2O2, is detected with an micro-electrode in the presence of either or both substrates, glucose and lactate, leading to a visualisation of the corresponding enzyme pattern and the lateral enzymatic activity. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:827 / 837
页数:11
相关论文
共 43 条
[1]  
Bard A.J., 1994, ELECTROANAL CHEM, V18, A., P243
[2]  
BILITEWSKI U, 1992, GBF MONOG SERIES, V17, P199
[3]   Application of redox enzymes for probing the antigen-antibody association at monolayer interfaces: Development of amperometric immunosensor electrodes [J].
Blonder, R ;
Katz, E ;
Cohen, Y ;
Itzhak, N ;
Riklin, A ;
Willner, I .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3151-3157
[4]   VOLTAMMETRY OF COVALENTLY IMMOBILIZED CYTOCHROME-C ON SELF-ASSEMBLED MONOLAYER ELECTRODES [J].
COLLINSON, M ;
BOWDEN, EF ;
TARLOV, MJ .
LANGMUIR, 1992, 8 (05) :1247-1250
[5]   Integrated microanalytical technology enabling rapid and automated protein identification [J].
Ekström, S ;
Önnerfjord, P ;
Nilsson, J ;
Bengtsson, M ;
Laurell, T ;
Marko-Varga, G .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :286-293
[6]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[7]  
HAUSSLING L, 1991, LANGMUIR, V7, P1837
[8]  
Hengstenberg A, 2000, CHEM-EUR J, V6, P1547, DOI 10.1002/(SICI)1521-3765(20000502)6:9<1547::AID-CHEM1547>3.3.CO
[9]  
2-3
[10]   Amperometric biosensors produced by immobilization of redox enzymes at polythiophene-modified electrode surfaces [J].
Hiller, M ;
Kranz, C ;
Huber, J ;
Bauerle, P ;
Schuhmann, W .
ADVANCED MATERIALS, 1996, 8 (03) :219-&