Stem design and dislocation after revision total hip arthroplasty - Clinical results and computer modeling

被引:58
作者
Barrack, RL [1 ]
Butler, RA [1 ]
Laster, DR [1 ]
Andrews, P [1 ]
机构
[1] Tulane Univ, Sch Med, Dept Orthopaed Surg, New Orleans, LA 70112 USA
关键词
THA; revision; dislocation; neck; taper; animation;
D O I
10.1054/arth.2001.28359
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effect of the size and shape of the neck and the taper of the femoral stein on dislocation rate after revision total hip arthroplasty was examined. Design I had a large (14/16), long taper with a circular neck cross-section; a fixed 42-mm offset; and a neck that was anteverted relative to the stem. Design II was characterized by a smaller (12/14), shorter taper; a trapezoidal neck cross-section; a progressive (40-50 mm) offset; and no neck anteversion relative to the stem. The stems were digitized and placed through a range of motion using virtual reality software, and the cross-sectional area of the neck, length of the taper, and total arc of motion before impingement between the neck and liner were compared. The dislocation rate at a minimum of 2 years' follow-up was 15.4% (8 of 52) for design I compared with 4.3% (2 of 46) for design II. This finding was consistent with the results of computer modeling, which showed that design I had a cross-sectional area that was 32% greater and a total arc of motion that was 76% less compared with design II. The results suggest that neck and taper design may be an important factor in dislocation after revision total hip arthroplasty.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 17 条
[1]  
ALBERTON GM, 2000, P 67 AM AC ORTH SURG, P566
[2]  
AMSTUTZ HC, 1991, HIP ARTHROPLASTY, P429
[3]  
BARRACK RL, IN PRESS ORTHOP CLIN
[4]  
BARRACK RL, 2000, INSTR COURSE LECT, V50, P275
[5]   The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[6]   Extended slide trochanteric osteotomy for revision total hip arthroplasty [J].
Chen, WM ;
McAuley, JP ;
Engh, CA ;
Hopper, RH ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1215-1219
[7]   Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty [J].
Cobb, TK ;
Morrey, BF ;
Ilstrup, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1361-1364
[8]   OPERATIVE CORRECTION OF AN UNSTABLE TOTAL HIP-ARTHROPLASTY [J].
DALY, PJ ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (09) :1334-1343
[9]   REVISION OF FAILED TOTAL HIP-ARTHROPLASTY [J].
EJSTED, R ;
OLSEN, NJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :57-60
[10]  
FRANKEL A, 1993, CLIN ORTHOP RELAT R, P209