Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System

被引:30
作者
Colbert, Agatha P. [1 ]
Yun, Jinkook [1 ]
Larsen, Adrian [2 ]
Edinger, Tracy [1 ]
Gregory, William L. [1 ]
Thong, Tran [1 ,3 ]
机构
[1] Natl Coll Nat Med, Helfgott Res Inst, Portland, OR 97201 USA
[2] Miridia Technol Inc, Meridian, ID USA
[3] Oregon Grad Inst, Dept Biomed Engn, Beaverton, OR 97006 USA
关键词
D O I
10.1093/ecam/nem060
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
Skin impedance at acupuncture points (APs) has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupunctures mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 k to 50 M at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes). The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI) were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6) and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5) against known resistors (580 k10 M) and capacitors (10 nF150 nF). Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r 0.87 and r 0.79, respectively). In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 43 条
[1]   Electrical impedance along connective tissue planes associated with acupuncture meridians [J].
Ahn A.C. ;
Wu J. ;
Badger G.J. ;
Hammerschlag R. ;
Langevin H.M. .
BMC Complementary and Alternative Medicine, 5 (1)
[2]   Evidence-based research in complementary and alternative medicine I: History [J].
Chiappelli, F ;
Prolo, P ;
Cajulis, OS .
EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2005, 2 (04) :453-458
[3]   Evidence-based research in complementary and alternative medicine II: The process of evidence-based research [J].
Chiappelli, F ;
Prolo, P ;
Rosenblum, M ;
Edgerton, M ;
Cajulis, OS .
EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2006, 3 (01) :3-12
[4]   Electrical properties of skin at moderate voltages: Contribution of appendageal macropores [J].
Chizmadzhev, YA ;
Indenbom, AV ;
Kuzmin, PI ;
Galichenko, SV ;
Weaver, JC ;
Potts, RO .
BIOPHYSICAL JOURNAL, 1998, 74 (02) :843-856
[5]  
Colbert AP, 2004, J ALTERN COMPLEM MED, V10, P610
[6]  
COLBERT AP, 2006, MED ACUPUNCTURE, V17, P12
[7]  
FRADEN J, 1979, AM J ACUPUNCTURE, V7, P137
[8]  
FUKUMOTO T, 2001, 23 ANN EMBS INT C IS
[9]  
Halek J, 1984, Acta Univ Palacki Olomuc Fac Med, V107, P51
[10]  
HYVARINEN J, 1977, MED BIOL, V55, P88