The analysis of synthetic organic, neutral polymers using nonaqueous capillary gel electrophoresis (NACGE)

被引:9
作者
Li, GD
Zhou, XJ
Wang, YH
Krull, IS
Mistry, K
Grinberg, N
Cortes, H
机构
[1] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
[2] Merck & Co Inc, Analyt Res Dept, Rahway, NJ 07065 USA
[3] Dow Chem Co USA, Organ Anal Grp, Analyt Sci, Midland, MI 48674 USA
关键词
synthetic organic polymers; nonaqueous capillary gel electrophoresis; molecular weight determinations; capillary electrophoresis;
D O I
10.1081/JLC-120030171
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe, in this paper, efforts to develop an optimized, replaceable, polyethylene oxide [PEO, aka polyethylene glycol (PEG)] gel in nonaqueous CGE (NACGE) for the analysis and characterization [molecular weights (MWs)] of a series of synthetic, organic polymers, mainly polystyrenes (PS) and polymethylmethacrylates (PMMA). The approach utilizes a novel combination of organic solvent run buffers, with varying levels of water and a hydrophobic cationic monomer, to induce electrophoretic flow or forces (EPF) in the organic polymers. The gel is fixed in place, using a coated capillary to prevent electroosmotic flow (EOF), so that only the analyte polymers move through the gel with time and applied voltage. Depending on the nature of the organic gel in the capillary and the buffer additives, polymers of known MWs can be made to migrate through the capillary with time, generating a standard MW vs. migration time calibration plot, analogous to what is derived for SEC analysis of the very same polymers. Though the range of this linearity appears rather limited, perhaps because of the nature of the PEO gels available, it is still possible to determine relative MWs for a series of known, standard PS and PMMA polymers, with reasonable accuracy and precision of such measurements.
引用
收藏
页码:939 / 964
页数:26
相关论文
共 49 条
[1]  
Altria K. D, 1996, CAPILLARY ELECTROPHO
[2]  
BAKER DR, 1995, TECHNIQUES ANAL CHEM
[3]  
Barth H.G., 1991, Modern methods of polymer characterization, V115
[4]   ULTRA-FAST HIGH-PERFORMANCE CAPILLARY SODIUM DODECYL-SULFATE GEL-ELECTROPHORESIS OF PROTEINS [J].
BENEDEK, K ;
GUTTMAN, A .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (02) :375-381
[5]  
BROWN PR, 1989, HIGH PERFORMANCE LIQ, pCH6
[6]  
CAMILLERI P, 1993, CAPILLARY ELECTROPHO
[7]  
CAZES J, 1977, LIQUID CHROMATOGRAPH
[8]  
CAZES J, 1980, LIQUID CHROMATOGRAPH, V2
[9]  
Cazes J., 2001, ENCY CHROMATOGRAPHY
[10]   Separations of anionic and cationic synthetic polyelectrolytes by capillary gel electrophoresis [J].
Clos, HN ;
Engelhardt, H .