T1-weighted MR-lymphography after intramammary administration of Gadomer-17 in pigs

被引:14
作者
Staatz, G
Spüntrup, E
Buecker, A
Misselwitz, B
Günther, RW
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Schering AG, MRI, Imaging Technol & Preclin Contrast Media Res, D-1000 Berlin, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2002年 / 174卷 / 01期
关键词
magnetic resonance imaging; contrast agents; MR-lymphography; sentinel lymph node; breast;
D O I
10.1055/s-2002-19551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the enhancement of regional lymph nodes and lymphatic vessels after intramammary injection of Gadomer-17. Materials and Methods: T-1-weighted MR-lymphography was performed in 8 domestic pigs after intramammary injection of 5-10 mumol/kg bodyweight (bw) Gadomer-17 on a 1.5 T-MR scanner. T-1-weighted 3D gradient-echo images were acquired 10 to 120 minutes after contrast material injection in coronal and sagittal planes. The contrast enhancement of the draining lymphatic system was qualitatively assessed by two radiologists applying a three grade scale. Results: T-1-Weighted MR-lymphography after intramammary injection of Gadomer-17 was feasible in each pig. A dose of 5 mumol/kg body weight Gadomer-17 was best suited for MR-lymphography of the mammary line and the draining lymphatic system. Enhancement of regional lymph nodes and lymphatic vessels was classified as good in 5, and excellent in three cases. Conclusions: Intramammary injection of Gadomer-17 allows for good quality T-1-weighted MR-lymphography of mammary gland draining regional lymph nodes and lymphatic vessels. This new technique might offer potential for the evaluation of the sentinel lymph node in patients with breast cancer.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 16 条
[1]   Breast cancer: Variables affecting sentinel lymph node visualization at preoperative lymphoscintigraphy [J].
Birdwell, RL ;
Smith, KL ;
Betts, BJ ;
Ikeda, DM ;
Strauss, HW ;
Jeffrey, SS .
RADIOLOGY, 2001, 220 (01) :47-53
[2]  
Cady B, 1996, ARCH SURG-CHICAGO, V131, P301
[3]   Prospective observational study of sentinel lymphadenectomy without further axillary dissection in patients with sentinel node-negative breast cancer [J].
Giuliano, AE ;
Haigh, PI ;
Brennan, MB ;
Hansen, NM ;
Kelley, MC ;
Ye, W ;
Glass, EC ;
Turner, RR .
JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (13) :2553-2559
[4]   Lymphoscintigraphy and lymphatic mapping for identification of sentinel lymph nodes [J].
Hsueh, EC ;
Turner, RR ;
Giuliano, AE .
WORLD JOURNAL OF SURGERY, 2001, 25 (06) :794-797
[5]   ASSESSMENT OF MORBIDITY FROM COMPLETE AXILLARY DISSECTION [J].
IVENS, D ;
HOE, AL ;
PODD, TJ ;
HAMILTON, CR ;
TAYLOR, I ;
ROYLE, GT .
BRITISH JOURNAL OF CANCER, 1992, 66 (01) :136-138
[6]   SURGICAL RESECTION AND RADIOLOCALIZATION OF THE SENTINEL LYMPH-NODE IN BREAST-CANCER USING A GAMMA-PROBE [J].
KRAG, DN ;
WEAVER, DL ;
ALEX, JC ;
FAIRBANK, JT .
SURGICAL ONCOLOGY-OXFORD, 1993, 2 (06) :335-340
[7]  
Mariani G, 2001, J NUCL MED, V42, P1198
[8]   Pharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent [J].
Misselwitz, B ;
Schmitt-Willich, H ;
Ebert, W ;
Frenzel, T ;
Weinmann, HJ .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2001, 12 (2-3) :128-134
[9]  
MORTON DL, 1992, ARCH SURG-CHICAGO, V127, P392
[10]   Precise MR-guided preoperative marking of breast lesions with an embolization coil [J].
Muller-Schimpfle, M ;
Stoll, P ;
Stern, W ;
Huppert, PE ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (02) :195-199