Three-dimensional volume reconstruction of extracellular matrix proteins in uveal melanoma from fluorescent confocal laser scanning microscope images

被引:20
作者
Bajcsy, P [1 ]
Lee, SC
Lin, A
Folberg, R
机构
[1] Univ Illinois, Natl Ctr Supercomp Applicat, Automated Learning Grp, Urbana, IL 61801 USA
[2] Univ Illinois, Ctr Canc, Chicago, IL 60612 USA
[3] Univ Illinois, Dept Pathol, Chicago, IL 60612 USA
关键词
automation; image registration; microscopy; three-dimensional volume reconstruction;
D O I
10.1111/j.1365-2818.2006.01539.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
The distribution of looping patterns of laminin in uveal melanomas and other tumours has been associated with adverse outcome. Moreover, these patterns are generated by highly invasive tumour cells through the process of vasculogenic mimicry and are not therefore blood vessels. Nevertheless, these extravascular matrix patterns conduct plasma. The three-dimensional (3D) configuration of these laminin-rich patterns compared with blood vessels has been the subject of speculation and intensive investigation. We have developed a method for the 3D reconstruction of volume for these extravascular matrix proteins from serial paraffin sections cut at 4 mu m thicknesses and stained with a fluorescently labelled antibody to laminin (Maniotis et al., 2002). Each section was examined via confocal laser-scanning focal microscopy (CLSM) and 13 images were recorded in the Z-dimension for each slide. The input CLSM imagery is composed of a set of 3D subvolumes (stacks of 2D images) acquired at multiple confocal depths, from a sequence of consecutive slides. Steps for automated reconstruction included (1) unsupervised methods for selecting an image frame from a subvolume based on entropy and contrast criteria, (2) a fully automated registration technique for image alignment and (3) an improved histogram equalization method that compensates for spatially varying image intensities in CLSM imagery due to photo-bleaching. We compared image alignment accuracy of a fully automated method with registration accuracy achieved by human subjects using a manual method. Automated 3D volume reconstruction was found to provide significant improvement in accuracy, consistency of results and performance time for CLSM images acquired from serial paraffin sections.
引用
收藏
页码:30 / 45
页数:16
相关论文
共 21 条
[1]   Quantitative serial sectioning analysis [J].
Alkemper, J ;
Voorhees, PW .
JOURNAL OF MICROSCOPY-OXFORD, 2001, 201 :388-394
[2]   DIGITAL IMAGING FLUORESCENCE MICROSCOPY - SPATIAL HETEROGENEITY OF PHOTOBLEACHING RATE CONSTANTS IN INDIVIDUAL CELLS [J].
BENSON, DM ;
BRYAN, J ;
PLANT, AL ;
GOTTO, AM ;
SMITH, LC .
JOURNAL OF CELL BIOLOGY, 1985, 100 (04) :1309-1323
[3]  
BROWN LG, 1992, ACM COMPUT SURV, V24, P326
[4]   First order error propagation of the Procrustes method for 3D attitude estimation [J].
Dorst, L .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2005, 27 (02) :221-229
[5]  
DUDA RO, 2001, PATTERN CLASSIFICAT
[6]   Vasculogenic mimicry [J].
Folberg, R ;
Maniotis, AJ .
APMIS, 2004, 112 (7-8) :508-525
[7]   A NEW TECHNIQUE FOR RETARDING FADING OF FLUORESCENCE - DPX-BME [J].
FRANKLIN, AL ;
FILION, WG .
STAIN TECHNOLOGY, 1985, 60 (03) :125-135
[8]  
Gonzalez Rafael C, 2002, DIGITAL IMAGE PROCES
[9]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[10]  
KOOPER R, 2005, P IEEE INT C WEB SER, V2, P709