Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database

被引:182
作者
Evans, JMM [1 ]
Newton, RW
Ruta, DA
MacDonald, TM
Stevenson, RJ
Morris, AD
机构
[1] Univ Dundee, Ninewells Hosp & Med Sch, Dept Clin Pharmacol, Med Monitoring Unit, Dundee DD1 9SY, Scotland
[2] Univ Dundee, Ninewells Hosp & Med Sch, Dept Epidemiol & Publ Hlth, Dundee DD1 9SY, Scotland
[3] Univ Dundee, Ninewells Hosp & Med Sch, Dept Med, Dundee DD1 9SY, Scotland
来源
BMJ-BRITISH MEDICAL JOURNAL | 1999年 / 319卷 / 7202期
基金
英国惠康基金;
关键词
D O I
10.1136/bmj.319.7202.83
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To investigate patterns of self monitoring of blood glucose concentration in diabetic patients who use insulin and to determine whether frequency of self monitoring is related to glycaemic control. Setting Diabetes database, Tayside, Scotland. Subjects Patients resident in Tayside in 1993-5 who were using insulin and were registered on the database and diagnosed with insulin dependent (type 1) or non-insulin dependent (type 2) diabetes before 1993. Main outcome measures Number of glucose monitoring reagent strips dispensed (reagent strip uptake) derived from records of prescriptions. First recorded haemoglobin A(1c), concentration in the study period, and reagent strips dispensed in the previous 6 months. Results Among 807 patients with type 1 diabetes, 128 (16%) did not redeem any prescriptions for glucose monitoring reagent strips in the 3 year study period. Only 161 (20%) redeemed prescriptions for enough reagent strips to test glucose daily. The corresponding figures for the 790 patients with type 2 diabetes who used insulin were 162 (21%; no strips) and 131 (17%; daily tests). Reagent strip uptake was influenced both by age and by deprivation category. There was a direct relation between uptake and glycaemic control for 258 patients (with recorded haemoglobin A(1c) concentrations) with type 1 diabetes. In a linear regression model the decrease in haemoglobin A(1c) concentration for every extra 180 reagent strips dispensed was 0.7%. For the 290 patients with type 2 diabetes who used insulin there was no such relation. Conclusions Self monitoring of blood glucose concentration is associated with improved glycaemic control in patients with type 1 diabetes. Regular self monitoring in patients with type 1 and type 2 diabetes is uncommon.
引用
收藏
页码:83 / 86
页数:4
相关论文
共 24 条
  • [1] [Anonymous], 1987, DIABETES CARE, V10, P95
  • [2] [Anonymous], NEW ENGLAND J MED
  • [3] PRIMARY NONCOMPLIANCE WITH PRESCRIBED MEDICATION IN PRIMARY-CARE
    BEARDON, PHG
    MCGILCHRIST, MM
    MCKENDRICK, AD
    MCDEVITT, DG
    MACDONALD, TM
    [J]. BRITISH MEDICAL JOURNAL, 1993, 307 (6908) : 846 - 848
  • [4] IMPACT OF SMBG ON CONTROL OF DIABETES AS MEASURED BY HBA1 - 3-YEAR SURVEY OF A JUVENILE IDDM CLINIC
    BELMONTE, MM
    SCHIFFRIN, A
    DUFRESNE, J
    SUISSA, S
    GOLDMAN, H
    POLYCHRONAKOS, C
    [J]. DIABETES CARE, 1988, 11 (06) : 484 - 488
  • [5] *BRIT MED ASS, 1998, BRIT NAT FORM, V35
  • [6] CARSTAIRS V R M, 1990, Health Bulletin (Edinburgh), V48, P162
  • [7] THE ROLE OF SELF-MONITORING OF BLOOD-GLUCOSE IN THE ROUTINE MANAGEMENT OF CHILDREN WITH INSULIN-DEPENDENT DIABETES-MELLITUS
    DANEMAN, D
    SIMINERIO, L
    TRANSUE, D
    BETSCHART, J
    DRASH, A
    BECKER, D
    [J]. DIABETES CARE, 1985, 8 (01) : 1 - 4
  • [8] Evans J. M. M., 1995, Pharmaceutical Medicine (London), V9, P177
  • [9] Self monitoring of glucose by people with diabetes: Evidence based practice
    Gallichan, M
    [J]. BRITISH MEDICAL JOURNAL, 1997, 314 (7085) : 964 - 967
  • [10] GILL GV, 1989, PRACTICAL DIABETES, V6, P77