Determination of polar priority phenols at parts per billion levels in water using on-line liquid-solid extraction followed by liquid chromatography with coulimetric detection

被引:41
作者
Puig, D [1 ]
Barcelo, D [1 ]
机构
[1] CSIC, CID, DEPT ENVIRONM CHEM, ES-08034 BARCELONA, SPAIN
关键词
water analysis; coulimetric detection; detection; LC; phenols; chlorophenols; nitrophenols;
D O I
10.1016/S0021-9673(97)00302-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-sensitivity method for the determination of polar phenolic compounds in water samples was developed. Water samples were preconcentrated using on-line solid-phase extraction with LiChrolut EN sorbent and afterwards were analyzed by liquid chromatography and dual coulimetric detection. The first electrode was set at low potential (250 mV) for sample clean up whereas the second one was used for analytical purposes. The system could not be used in its reductive form due to the lack of reversibility on the electrochemical behaviour of nitrophenols. Detection limits at part per trillion level were obtained using only 5 ml of water. Additionally, the large cell constant of the coulimetric detector lead to low values of coefficients of variation (+/-6) when working with river water. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 17 条
[1]   SIMULTANEOUS DETERMINATION OF 27 PHENOLS AND HERBICIDES IN WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH MULTIELECTRODE ELECTROCHEMICAL DETECTION [J].
ACHILLI, G ;
CELLERINO, GP ;
DERIL, GM ;
BIRD, S .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :357-362
[2]   DETERMINATION OF PHENOLIC-COMPOUNDS IN SURFACE-WATER USING ONLINE LIQUID-CHROMATOGRAPHIC PRECOLUMN-BASED COLUMN-SWITCHING TECHNIQUES [J].
BROUWER, ER ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 678 (02) :223-231
[3]  
DICORCIA A, 1994, J AOAC INT, V77, P446
[4]  
*EPA, 1984, FED REGISTER, P153
[5]  
*EPA, 1984, FED REG 1026, P58
[6]   DETERMINATION OF PHENOLS IN SEA-WATER BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION AFTER ENRICHMENT BY USING SOLID-PHASE EXTRACTION CARTRIDGES AND DISKS [J].
GALCERAN, MT ;
JAUREGUI, O .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :75-84
[7]   OPTIMIZATION OF ELECTROCHEMICAL DETECTION IN THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF LIGNIN PHENOLICS FROM LIGNOCELLULOSIC BY-PRODUCTS [J].
GALLETTI, GC ;
PICCAGLIA, R ;
CONCIALINI, V .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :439-450
[8]   SURFACE-WATER ANALYSIS (TRACE-ORGANIC CONTAMINANTS) AND EC REGULATIONS [J].
HENNION, MC ;
PICHON, V ;
BARCELO, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :361-372
[9]  
Huesgen A. G., 1991, LC GC International, V4, P40
[10]   ANODIC-OXIDATION PATHWAYS OF PHENOLIC COMPOUNDS .2. STEPWISE ELECTRON TRANSFERS AND COUPLED HYDROXYLATIONS [J].
PAPOUCHADO, L ;
SANDFORD, RW ;
PETRIE, G ;
ADAMS, RN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1975, 65 (01) :275-284