Determination of phenol in the presence of its principal degradation products in water during a TiO2-photocatalytic degradation process by three-dimensional excitation-emission matrix fluorescence and parallel factor analysis

被引:38
作者
Bosco, MV [1 ]
Garrido, M [1 ]
Larrechi, MS [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt & Organ Chem, Fac Chem, Tarragona 43007, Spain
关键词
phenol; PARAFAC model; photodegradation reactions; fluorescence; excitation-emission matrix;
D O I
10.1016/j.aca.2005.12.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a simple and rapid way of monitoring a photocatalytic degradation of phenol in aqueous suspensions of TiO2. A three-way analytical methodology based on fluorescence excitation-emission matrix (EEM) and parallel factor analysis (PARAFAC) was developed to resolve the species present in the reaction mixture and quantify the concentration of phenol and its principal degradation products throughout the degradation. Parameters such as core consistency, fit% and correlation coefficients between recovered and pure spectra were used to determine the appropriate number of factors for the PARAFAC model. The accuracy of the model was evaluated by the root mean square error of prediction (RMSEP). Using a four-factors PARAFAC model, phenol, hydroquinone, resorcinol and catechol, were satisfactorily determined. The proposed method is an interesting alternative to the traditional techniques normally used for monitoring degradation reactions. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:240 / 247
页数:8
相关论文
共 31 条
[1]  
ANDERSSON CA, 2004, N WAY TOOLBOX MATLAB
[2]  
[Anonymous], 1998, Multi-way Analysis in the Food Industry: Models, Algorithms and Applications
[3]  
BLESA MA, 2001, ELIMINACION CONTAMIN, P103
[4]   Single measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water .2. Calibration and quantitation of naphthalene and styrene [J].
Booksh, KS ;
Muroski, AR ;
Myrick, ML .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3539-3544
[5]   A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[6]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[7]   Exploratory study of sugar production using fluorescence spectroscopy and multi-way analysis [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :133-147
[8]  
da Silva JCGE, 2002, ANAL CHIM ACTA, V453, P105
[9]   Resolution of phenol, o-cresol, m-cresol and p-cresol mixtures by excitation fluorescence using partial least-squares (PLS) multivariate calibration [J].
delOlmo, M ;
Diez, C ;
Molina, A ;
deOrbe, I ;
Vilchez, JL .
ANALYTICA CHIMICA ACTA, 1996, 335 (1-2) :23-33
[10]   Relationship between TiO2 particle size and reactor diameter in solar photoreactors efficiency [J].
Fernández-Ibáñez, P ;
Malato, S ;
de las Nieves, FJ .
CATALYSIS TODAY, 1999, 54 (2-3) :195-204