The impact of distributed synchronous generators on quality of electricity supply and transient stability of real distribution network

被引:34
作者
Calderaro, V. [2 ]
Milanovic, J. V. [1 ]
Kayikci, M. [1 ]
Piccolo, A. [2 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
[2] Univ Salerno, Dept Informat & Elect Engn DIIIE, Salerno, Italy
关键词
Distributed generation; Distribution network; Transient analysis; Steady state analysis;
D O I
10.1016/j.epsr.2008.05.022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
The paper investigates steady state and transient impact of Distributed Synchronous Generators (DSG) oil a real Italian distribution network. Before connecting or allowing the connection of DSG, the worst operating scenarios have to be analyzed to guarantee that the network voltages remain within allowed ranges. A voltage profile variation and steady state voltage regulation are analyzed, therefore following connection of DSG. Transient analysis is also performed in order to analyze the impact of DSG on stability and protection system. Further, the islanding operating mode of the network is considered having in mind that the DSG Could provide additional to the load in the absence of the main power supply. In particular, in the event of a supply outage, the temporary islanding operation of DSG might improve the continuity of service and such contribute to the overall quality of electricity supply to the customers. (C) 2008 Elsevier B.V. All rights reserved. (c) 2008 Elsevier B.
引用
收藏
页码:134 / 143
页数:10
相关论文
共 20 条
[1]
Ackermann T, 2002, IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS, P1357, DOI 10.1109/TDC.2002.1177677
[2]
AGUSTONI A, 2002, P 10 INT C HARM QUAL
[3]
[Anonymous], U POW ENG C 2004 UPE
[4]
Azmy A.M., 2005, Power Engineering Society General Meeting, 2005, 12-16 June 2005, V2, P1056
[5]
CALDERARO V, 2005, P UPEC 2005 C SEPT C
[6]
CHENGTING H, 2005, POW ENG SOC GEN M IE, V3, P2962
[7]
ENEL, 2004, 4452 DK
[8]
ENEL, 2004, 5600 DK
[9]
Comparative analysis between synchronous and induction machines for distributed generation applications [J].
Freitas, W ;
Vieira, JCM ;
Morelato, A ;
da Silva, LCP ;
da Costa, VF ;
Lemos, FAB .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (01) :301-311
[10]
The adverse effects of excitation system var and power factor controllers - Discussion [J].
Murdoch, A ;
Lawson, RA .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) :1643-1644