Passive sampling of herbicides combined with effect analysis in algae using a novel high-throughput phytotoxicity assay (Maxi-Imaging-PAM)

被引:56
作者
Escher, BI [1 ]
Quayle, P
Muller, R
Schreiber, U
Mueller, JF
机构
[1] Swiss Fed Inst Aquat Sci & Technol, Eawag, Dept Environm Toxicol, CH-8600 Dubendorf, Switzerland
[2] Univ Queensland, Natl Res Ctr Environm Toxicol, EnTox, Brisbane, Qld 4072, Australia
[3] Univ Wurzburg, Lehrstuhl Bot 1, Julius von Sachs Inst Biowissensch, D-97082 Wurzburg, Germany
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2006年 / 8卷 / 04期
关键词
D O I
10.1039/b517512g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We propose to combine a passive sampler for polar organic compounds ( POS) with a specific bioassay for phytotoxicity to assess the hazard of herbicidal compounds in surface waters. The POS consisted of an Empore (TM) disk coated with styrenedivinylbenzene deployed in a Teflon housing, which has relatively high sampling rates ( e. g., approximately 1 L d (-1) for diuron). POS were deployed for 5 days in a small- scale field study in South East Queensland, Australia, in a relatively pristine environment and an urban environment to explore sensitivity towards herbicides and potential influences of non- herbicidal pollutants. Besides chemical analysis of 8 herbicides, a novel bioassay ( Maxi- Imaging- PAM, IPAM) was employed to assess the phytotoxic effects of water samples and POS extracts. The IPAM allows rapid assessment of photosynthetic quantum yields of a large number of samples via chlorophyll-fluorescence imaging and the saturation pulse method. Sampling rates for several herbicides from laboratory calibrations were found to be applicable under field conditions. Toxic equivalent concentrations ( with reference to the herbicide diuron) were computed from the concentrations determined by chemical analysis and the relative potency ( also termed toxic equivalence factor) of the detected herbicides. There was good agreement between diuron equivalent concentrations from chemical analysis and diuron equivalent concentrations determined with the IPAM.
引用
收藏
页码:456 / 464
页数:9
相关论文
共 27 条
[1]   Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments [J].
Alvarez, DA ;
Petty, JD ;
Huckins, JN ;
Jones-Lepp, TL ;
Getting, DT ;
Goddard, JP ;
Manahan, SE .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2004, 23 (07) :1640-1648
[2]   Including mixtures in the determination of water quality criteria for herbicides in surface water [J].
Chèvre, N ;
Loeppe, C ;
Singer, H ;
Stamm, C ;
Fenner, K ;
Escher, BI .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (02) :426-435
[3]   Pharmaceuticals and personal care products in the environment: Agents of subtle change? [J].
Daughton, CG ;
Ternes, TA .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :907-938
[4]   Development of automated high-throughput ecotoxicity and genotoxicity test systems and fields of application [J].
Eisentraeger, A ;
Brinkmann, C ;
Michel, K ;
Hahn, S ;
Huettner, M ;
Weber, G .
WATER SCIENCE AND TECHNOLOGY, 2004, 50 (05) :109-114
[5]   In vitro assessment of modes of toxic action of pharmaceuticals in aquatic life [J].
Escher, BI ;
Bramaz, N ;
Eggen, RIL ;
Richter, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (09) :3090-3100
[6]   Measurement of free concentrations using negligible depletion-solid phase microextraction (nd-SPME) [J].
Heringa, MB ;
Hermens, JLM .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (09) :575-587
[7]   LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
HUCKINS, JN ;
MANUWEERA, GK ;
PETTY, JD ;
MACKAY, D ;
LEBO, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) :2489-2496
[8]   Polar organic chemical integrative sampling and liquid chromatography-electrospray/ion-trap mass spectrometry for assessing selected prescription and illicit drugs in treated sewage effluents [J].
Jones-Lepp, TL ;
Alvarez, DA ;
Petty, JD ;
Huckins, JN .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2004, 47 (04) :427-439
[9]  
KINGSTON J, 2001, Patent No. 2353860
[10]   Development of a novel passive sampling system for the time-averaged measurement of a range of organic pollutants in aquatic environments [J].
Kingston, JK ;
Greenwood, R ;
Mills, GA ;
Morrison, GM ;
Persson, LB .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (05) :487-495