Microfabricated flow chamber for fluorescence-based chemistries and stopped-flow injection cytometry

被引:16
作者
Hodder, PS [1 ]
Blankenstein, G [1 ]
Ruzicka, J [1 ]
机构
[1] TECH UNIV DENMARK,MIKROELEKTR CTR,DK-2800 LYNGBY,DENMARK
关键词
flow injection; microfabrication; enzyme; fluorescence; microscopy; flow cytometry;
D O I
10.1039/a701750b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfabricated flow chamber (MFC) suitable for performing liquid-based fluorimetric assays is introduced, Precision delivery of microliter volumes of sample and reagent to the MFC is accomplished by a double-syringe-pump flow injection analysis (FIA) apparatus. The FIA-MFC system also combines the 'sheath flow' technique (traditionally used in flow cytometry) and stopped-flow FIA as a way to allow sample and reagent streams to be mixed reproducibly, The applicability of this FIA-MFC system to bioanalytical assays is demonstrated by performing an enzymatic assay with an artificial fluorigenic substrate to determine the activity of Savinase, a proteolytic enzyme, When coupled to a fluorescence microscope platform, quantitative analysis of the reaction product is possible, Experiments showed that the FIA-MFC system was capable of performing the assay with good reproducibility of injection (1.5%), and linearity of response (r(2) = 0.9997) in activity ranges of analytical interest, Owing to the incorporation of flow cytometry sheath flow principles into an FIA format, the FIA-MFC system is a suitable tool for cytometric studies.
引用
收藏
页码:883 / 887
页数:5
相关论文
共 20 条
[1]  
BIRD RB, 1960, TRANSPORT PHENOMENA, pCH1
[2]  
BLANKENSTEIN G, 1996, ANAL METHOD INSTRUM, P82
[3]   DEVELOPERS OF NOVEL DNA SEQUENCERS CLAIM MAJOR PERFORMANCE ADVANCES [J].
BORMAN, S .
CHEMICAL & ENGINEERING NEWS, 1995, 73 (30) :37-39
[4]  
BRNEBJERG J, 1996, P 9 INT WORKSH MICR, P441
[5]   EXPLOITING STOPPED-FLOW INJECTION METHODS FOR QUANTITATIVE CHEMICAL-ASSAYS [J].
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :11-21
[6]   ELECTROOSMOSIS - A RELIABLE FLUID PROPULSION SYSTEM FOR FLOW-INJECTION ANALYSIS [J].
DASGUPTA, PK ;
LIU, S .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1792-1798
[7]   MANIPULATION OF SAMPLE FRACTIONS ON A CAPILLARY ELECTROPHORESIS CHIP [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2284-2287
[8]   A GENERIC FIA SYSTEM FOR DETERMINATION OF ENZYME-ACTIVITIES - ASSAY OF CELLULASE [J].
HANSEN, EH ;
JENSEN, A .
TALANTA, 1993, 40 (12) :1891-1897
[9]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10
[10]  
KACHEL V, 1990, FLOW CYTOMETRY SORTI, pCH3