Report on the dosimetry of a new design 125Iodine brachytherapy source

被引:42
作者
Wallace, RE [1 ]
Fan, JJ
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90095 USA
[2] N Amer Sci Inc, Calibrat Lab, N Hollywood, CA 91605 USA
关键词
brachytherapy; source; Iodine-125; I-125; dosimetry;
D O I
10.1118/1.598737
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dosimetric measurements were performed to characterize a new I-125 source that is a variant design of an existing source, designated as MED3631-A/S, and that has application in interstitial brachytherapy. The new source, designated as MED3631-A/M, has centralized radio-opaque markers. In the original MED3631-A/S source, the radio-opaque markers are separated. Thermoluminescent dosimeters were placed in phantom to measure transverse axis and angular dose profiles over a range of distances from 0.5 to 7 cm. The data were analyzed in terms of parameters recommended by AAPM Task Group No. 43. Tabular data evaluated in liquid water are provided for the dose-rate constant, Lambda, radial dose function, g(r), the anisotropy function, F(r, theta), the anisotropy factor, phi(an)(r), the point-source approximation anisotropy constant, <(phi)over bar>(an). The dose-rate constant was determined by an absolute method using a Cobalt-60 reference and by relative measurements using calibrated I-125 source(s). Values of the dose-rate constant are provided for both the 1985 and 1999 NIST air-kerma strength standards. The new source is comparable to both the MED3631-A/S and the model 6702 I-125 source designs, demonstrating equivalent radial dose function, g(r). Differences in the value of the dose-rate constant, Lambda, and the anisotropy of the dose distributions in phantom are discussed in light of the improved isotropy of the new design, the MED3631-A/M source, and the uncertainty involved in the dose measurement using a Cobaltd-60 reference. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02009-X].
引用
收藏
页码:1925 / 1931
页数:7
相关论文
共 29 条
[1]   Clinical impact of implementing the recommendations of AAPM task group 43 on permanent prostate brachytherapy using 125I [J].
Bice, WS ;
Prestidge, BR ;
Prete, JJ ;
Dubois, DF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05) :1237-1241
[2]   DOSE-RATE DETERMINATION FOR I-125 SEEDS [J].
CHIUTSAO, ST ;
ANDERSON, LL ;
OBRIEN, K ;
SANNA, R .
MEDICAL PHYSICS, 1990, 17 (05) :815-825
[3]  
DASKALOV GM, 1990, MED PHYS, V17, P1032
[4]  
FURHANG EE, 1998, MED PHYS, V25, P2269
[5]   POLYETHYLENE-BASED WATER-EQUIVALENT PHANTOM MATERIAL FOR X-RAY DOSIMETRY AT TUBE VOLTAGES FROM 10 TO 100 KV [J].
HERMANN, KP ;
GEWORSKI, L ;
MUTH, M ;
HARDER, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (11) :1195-1200
[6]  
*ICWG, 1990, PHYS BIOL CLIN CONS
[8]   Report of the ad hoc committee of the AAPM radiation therapy committee on 125I sealed source dosimetry [J].
Kubo, HD ;
Coursey, BM ;
Hanson, WF ;
Kline, RW ;
Seltzer, SM ;
Shuping, RE ;
Williamson, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (03) :697-702
[9]  
LI Z, 1998, COMMUNICATION
[10]   PHYSICAL DOSIMETRY OF I-125 SEEDS OF A NEW DESIGN FOR INTERSTITIAL IMPLANT [J].
LING, CC ;
YORKE, ED ;
SPIRO, IJ ;
KUBIATOWICZ, D ;
BENNETT, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (11) :1747-1752