Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses

被引:121
作者
Auerbach, Edward J. [1 ]
Xu, Junqian [1 ]
Yacoub, Essa [1 ]
Moeller, Steen [1 ]
Ugurbil, Kamil [1 ]
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
parallel imaging; multiband; simultaneous multislice; diffusion; fMRI; WHOLE-BRAIN; FMRI; MRI; COLUMNS;
D O I
10.1002/mrm.24719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate an alternative method for generating multibanded radiofrequency (RF) pulses for use in multiband slice-accelerated imaging with slice-GRAPPA unaliasing, substantially reducing the required peak power without bandwidth compromises. This allows much higher accelerations for spin-echo methods such as SE-fMRI and diffusion-weighted MRI where multibanded slice acceleration has been limited by available peak power. Theory and Methods: Multibanded time-shifted RF pulses were generated by inserting temporal shifts between the applications of RF energy for individual bands, avoiding worst-case constructive interferences. Slice profiles and images in phantoms and human subjects were acquired at 3 T. Results: For typical sinc pulses, time-shifted multibanded RF pulses were generated with little increase in required peak power compared to single-banded pulses. Slice profile quality was improved by allowing for higher pulse bandwidths, and image quality was improved by allowing for optimum flip angles to be achieved. Conclusion: A simple approach has been demonstrated that significantly alleviates the restrictions imposed on achievable slice acceleration factors in multiband spin-echo imaging due to the power requirements of multibanded RF pulses. This solution will allow for increased accelerations in diffusion-weighted MRI applications where data acquisition times are normally very long and the ability to accelerate is extremely valuable. Magn Reson Med 69:12611267, 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1261 / 1267
页数:7
相关论文
共 36 条
[1]  
Andersson J., 2012, P 20 ANN M ISMRM MEL, P2426
[2]  
[Anonymous], 18 ANN M ORG HUM BRA
[3]   NMR MICROSCOPY OF DYNAMIC DISPLACEMENTS - K-SPACE AND Q-SPACE IMAGING [J].
CALLAGHAN, PT ;
ECCLES, CD ;
XIA, Y .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (08) :820-822
[4]   VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[5]   TISSUE PERFUSION IN HUMANS STUDIED BY FOURIER VELOCITY DISTRIBUTION, LINE SCAN, AND ECHO-PLANAR IMAGING [J].
FEINBERG, DA ;
JAKAB, PD .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :280-293
[6]   Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging [J].
Feinberg, David A. ;
Moeller, Steen ;
Smith, Stephen M. ;
Auerbach, Edward ;
Ramanna, Sudhir ;
Glasser, Matt F. ;
Miller, Karla L. ;
Ugurbil, Kamil ;
Yacoub, Essa .
PLOS ONE, 2010, 5 (12)
[7]   Two methods for peak RF power minimization of multiple inversion-band pulses [J].
Goelman, G .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :658-665
[8]   CHEMICAL-SHIFT IMAGING WITH PHASE-ENCODING RF PULSES [J].
HENNIG, J .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :289-298
[9]   Whole brain, high resolution spin-echo resting state fMRI using PINS multiplexing at 7 T [J].
Koopmans, Peter J. ;
Boyacioglu, Rasim ;
Barth, Markus ;
Norris, David G. .
NEUROIMAGE, 2012, 62 (03) :1939-1946
[10]  
Larkman DJ, 2001, J MAGN RESON IMAGING, V13, P313, DOI 10.1002/1522-2586(200102)13:2<313::AID-JMRI1045>3.3.CO