Adult patient doses in interventional neuroradiology

被引:35
作者
Gkanatsios, NA
Huda, W
Peters, KR
机构
[1] Univ Florida, Dept Radiol, Gainesville, FL 32610 USA
[2] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
关键词
dosimetry; surface dose; energy imparted; effective dose; neuroradiology;
D O I
10.1118/1.1470206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
We investigated radiation doses to 149 adult patients who underwent interventional neuroradiologic procedures. consisting of 132 patients who had diagnostic imaging examinations and 17 patients who had therapeutic procedures. The interventional procedures were carried out on a biplane system capable of performing fluoroscopy and digital subtraction angiography (DSA). The x-ray imaging system was inter-faced to a patient dosimetry system, which computed surface (skin) doses based on the selected radiographic technique factors in each of the radiographic and fluoroscopic imaging modes. For each patient, an assessment was made of the maximum surface dose received during the procedure. which predicts the possibility of inducing deterministic effects. Knowledge of the surface doses, beam quality and x-ray cross sectional area permitted the computation of the total energy imparted to each patient. Energy imparted values were converted to effective dose, which provides an estimate of the stochastic radiation risk to the patient. The median surface dose for the frontal plane during diagnostic imaging examinations was 1.3 Gy, with a maximum surface dose of 5.1 Gy. The median surface dose for the frontal plane during therapeutic procedures was 2.8 Gy with a maximum surface dose of 5.0 Gy. Ratios of the lateral to frontal median surface doses were 0.47 for diagnostic examinations and 0.68 for interventional procedures. The median energy imparted was 1.8 J during fluoroscopy. and 4.3 J during radiography, showing that on average. 66% of the patient exposure comes from radiographic imaging (DSA). For diagnostic examinations, the median patient effective dose was 33 mSv, with a maximum of 152 mSv. For therapeutic procedures, the median patient effective dose was 74 mSv, with a maximum of 156 mSv. In interventional neuroradiology, surface doses could induce deterministic effects, and the corresponding effective doses are noticeably higher than those normally encountered in diagnostic radiology. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:717 / 723
页数:7
相关论文
共 35 条
[1]
BERGERON P, 1994, AM J NEURORADIOL, V15, P1809
[2]
BERTHELSEN B, 1991, ACTA RADIOL, V32, P492
[3]
Connors JI, 1999, INTERVENTIONAL NEURO
[4]
CORONARY ANGIOGRAPHY - AN ANALYSIS OF RADIOGRAPHIC PRACTICE IN THE UK [J].
COULDEN, RA ;
READMAN, LP .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784) :327-331
[5]
FEYGELMAN VM, 1992, AM J NEURORADIOL, V13, P845
[6]
Effects of low doses of radiation [J].
Fry, RJM .
HEALTH PHYSICS, 1996, 70 (06) :823-827
[7]
Evaluation of an on-line patient exposure meter in neuroradiology [J].
Gkanatsios, NA ;
Huda, W ;
Peters, KR ;
Freeman, JA .
RADIOLOGY, 1997, 203 (03) :837-842
[8]
Computation of energy imparted in diagnostic radiology [J].
Gkanatsios, NA ;
Huda, W .
MEDICAL PHYSICS, 1997, 24 (04) :571-579
[9]
GKANATSIOS NA, 1995, THESIS U FLORIDA GAI
[10]
GKANATSIOS NA, 2001, C P SPIE, V4320