Distractive properties of a threaded interbody fusion device - An in vivo model

被引:86
作者
Sandhu, HS
Turner, S
Kabo, JM
Kanim, LEA
Liu, D
Nourparvar, A
Delamarter, RB
Dawson, EG
机构
[1] UNIV CALIF LOS ANGELES, SCH MED, UCLA COMPREHENS SPINE CTR, LOS ANGELES, CA 90095 USA
[2] COLORADO STATE UNIV, COLL VET MED & BIOMED SCI, FT COLLINS, CO 80523 USA
关键词
cage; intervertebral distraction; sheep lumbar spine; spine fusion; titanium;
D O I
10.1097/00007632-199605150-00013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Twenty sheep underwent anterior lumbar interbody fusions with either a threaded titanium interbody fusion device (cage, n = 8), autogenous iliac crest dowel graft (autograft, n = 6), or interbody decortication only (sham, n = 6). Two sheep had misplaced cages and were excluded. Sheep were killed after 6 months. Objectives. To determine whether this model is useful for examining the distractive and fixation properties of interbody fusion cages. Summary of Background Data. Interbody fusion cages are used in anterior lumbar interbody fusion procedures to provide immediate intersegmental fixation and to distract and preserve interbody height. The process of physiologic anchorage by bone ingrowth into such devices is under investigation. Methods. Sheep were radiographed immediately after surgery and 2, 4, and 6 months after surgery. Interbody distraction and angulation were measured with a digital photo image analyzer at each time point. After the sheep were killed, stiffness to flexion, extension, and lateral bending moments were measured. Twelve untreated cadaver spines were also tested for comparison. Results. After surgery, interbody distraction successfully occurred in cage and autograft-implanted sites. Loss of interbody height ensued, however, in all groups during the first 2 months. Percentage loss of height was lowest in cage sites. By 6 months, only cage sites remained distracted beyond normal. Fusions in all groups were stiffer than untreated spines. Autograft sites were stiffer than cage sites to lateral bending. Sham sites were stiffer than cage and autograft sites to flexion, but this likely resulted from complete intervertebral collapse. Conclusion. Despite early subsidence, interbody fusion cages successfully distracted and preserved interbody spaces. This model is useful for investigating methods of improving distraction and stabilization.
引用
收藏
页码:1201 / 1210
页数:10
相关论文
共 23 条
[1]  
AARON AD, 1994, ORTHOPEDICS, V17, P41
[2]  
BAGBY GW, 1988, ORTHOPEDICS, V11, P931
[3]  
BOYD LM, 1995, 2 INT M ADV SPIN TEC
[4]   INTERBODY LUMBAR FUSION USING A CARBON-FIBER CAGE IMPLANT VERSUS ALLOGRAFT BONE - AN INVESTIGATIONAL STUDY IN THE SPANISH GOAT [J].
BRANTIGAN, JW ;
MCAFEE, PC ;
CUNNINGHAM, BW ;
WANG, H ;
ORBEGOSO, CM .
SPINE, 1994, 19 (13) :1436-1444
[5]   A MODIFIED CLOWARDS TECHNIQUE FOR ARTHRODESIS OF THE NORMAL METACARPOPHALANGEAL JOINT IN THE HORSE [J].
CRAWLEY, GR ;
GRANT, BD ;
WHITE, KK ;
BARBEE, DD ;
GALLINA, AM ;
RATZLAFF, MH .
VETERINARY SURGERY, 1988, 17 (03) :117-127
[6]  
DEBOWES RM, 1984, AM J VET RES, V45, P191
[7]   COMPARISON OF DISK SPACE HEIGHTS AFTER ANTERIOR LUMBAR INTERBODY FUSION [J].
DENNIS, S ;
WATKINS, R ;
LANDAKER, S ;
DILLIN, W ;
SPRINGER, D .
SPINE, 1989, 14 (08) :876-878
[8]  
Fang H S, 1964, Clin Orthop Relat Res, V35, P16
[9]  
GILL K, 1989, LUMBAR INTERBODY FUS
[10]  
Holte D C, 1994, Eur Spine J, V3, P32, DOI 10.1007/BF02428314