A two-year, three institution experience with the medtronic octopus: Systematic off-pump surgery

被引:43
作者
Spooner, TH
Hart, JC
Pym, J
机构
[1] Pk Nicollet Clin, Hlth Syst Minnesota, St Louis Pk, MN 55426 USA
[2] Pinnacle Hlth, Harrisburg, PA USA
[3] Queens Univ, Kingston, ON, Canada
关键词
D O I
10.1016/S0003-4975(99)00966-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The popularity of beating heart coronary artery bypass (CAB) has grown with the development of mechanical stabilizers. Multicenter study offers an opportunity to examine methods and risk relating to this practice. Methods. The experience since March 1997, utilizing both the original Il Medtronic Octopus system and the second-generation, retractor-mounted, Octopus II for beating heart CAB (Medtronic, Inc, Minneapolis, MN), was retrospectively reviewed at three institutions. Results. Four hundred fifty-six patients completed Octopus CAB (Medtronic, Inc), performed through left thoracotomy (54), partial (33), or full (374) sternotomy, and epigastric (3) incisions with an average of 1.9 grafts/patient. Morbidities were reviewed: transfusion (20.6%), reoperation for bleeding (1.0%), atrial fibrillation (13.3%), completed stroke (0.2%), perioperative myocardial infarction (0.8%), and new intraaortic balloon pump (IABP) (0.4%), without episodes of deep sternal infection or renal failure. The mortality rate (0.32%), when compared to the Society of Thoracic Surgeons' (STS)-predicted mortality (1.37% and 2.36%) at two institutions, was significantly less (p < 0.05). Twelve nonurgent and one urgent conversion to cardiopulmonary bypass occurred. Six patients have required reintervention on bypassed vessels. Conclusions. To facilitate lateral and inferior wall grafting a variety of techniques were utilized, including positioning, sternal and pericardial mobilization, and a new pericardial-based sling retractor, all designed to improve exposure while maintaining hemodynamic stability. The Octopus devices were safely applied with low morbidity and mortality utilizing varied operative approaches at three institutions. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:1478 / 1481
页数:4
相关论文
共 7 条
  • [1] Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device (''Octopus'')
    Borst, C
    Jansen, EWL
    Tulleken, CAF
    Grundeman, PF
    Beck, HJM
    vanDongen, JWF
    Hodde, KC
    Bredee, JJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) : 1356 - 1364
  • [2] Left anterior descending coronary artery grafting via left anterior small thoracotomy without cardiopulmonary bypass
    Calafiore, AM
    DiGiammarco, G
    Teodori, G
    Bosco, G
    DAnnunzio, E
    Barsotti, A
    Maddestra, N
    Paloscia, L
    Vitolla, G
    Sciarra, A
    Fino, C
    Contini, M
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (06) : 1658 - 1663
  • [3] AN ALTERNATIVE APPROACH TO ISOLATED CIRCUMFLEX CORONARY-BYPASS REOPERATIONS
    CHEUNG, D
    FLEMMA, RJ
    MULLEN, DC
    LEPLEY, D
    [J]. ANNALS OF THORACIC SURGERY, 1982, 33 (03) : 302 - 303
  • [4] Full-spectrum cardiac surgery through a minimal incision: Mini-sternotomy (lower half) technique
    Doty, DB
    DiRusso, GB
    Doty, JR
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (02) : 573 - 577
  • [5] CIRCUMFLEX EXPOSURE USING A CARDIAC SLING
    GALVIN, IF
    NEWMAN, DC
    [J]. ANNALS OF THORACIC SURGERY, 1990, 49 (05) : 833 - 834
  • [6] JANKE WH, 1974, J THORAC CARDIOV SUR, V67, P883