Relation of final lumen dimensions in saphenous vein grafts after stent implantation to outcome

被引:22
作者
Iakovou, I [1 ]
Dangas, G [1 ]
Mintz, GS [1 ]
Mehran, R [1 ]
Kobayashi, Y [1 ]
Aymong, ED [1 ]
Hirose, M [1 ]
Ashby, DT [1 ]
Lansky, AJ [1 ]
Stone, GW [1 ]
Leon, MB [1 ]
Moses, JW [1 ]
机构
[1] Lenox Hill Heart & Vasc Inst, Cardiovasc Res Fdn, New York, NY 10022 USA
关键词
D O I
10.1016/j.amjcard.2003.12.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Larger final lumen dimensions after percutaneous coronary interventions in native coronary arteries lead to lower restenosis rates. We sought to determine the impact of stent expansion, as assessed by intravascular ultrasound, on clinical results of stent implantation in saphenous vein grafts (SVGs). We identified 226 consecutive patients who underwent intravascular ultrasound-guided stenting of 234 de novo SVG lesions. Patients were divided into 2 groups based on the final stent cross-sectional area (CSA): group I (stent CSA <100% of the reference lumen CSA, n = 176 patients, 182 lesions) and group II (stent CSA greater than or equal to100% of the reference lumen CSA, In = 50 patients, 52 lesions). Baseline patient characteristics were similar between the 2 groups with the exception of smaller lesions in group II. More aggressive stent expansion (group 11) was associated with (1) increased rates of in-hospital non-Q-wave myocardial infarction (29% vs 17%, p = 0.05), (2) any myocardial infarction (26% vs 8%, p = 0.003) at 1-year follow-up, and (3) no improvement in target vessel revascularization at 1 year (31% vs; 26%, p = 0.3). Aggressive stent expansion in SVG lesions resulted in higher myocardial infarction rates and, unlike native arteries, no improvement in target vessel revascularization rate at 1 year. A less aggressive stent implantation strategy in SVGs than in native coronary lesions appears prudent. (C) 2004 by Excerpta Medica, Inc.
引用
收藏
页码:963 / 968
页数:6
相关论文
共 28 条
[1]   Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions [J].
Abizaid, AS ;
Mintz, GS ;
Mehran, R ;
Abizaid, A ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Wu, HS ;
Pappas, C ;
Kent, KM ;
Leon, MB .
CIRCULATION, 1999, 100 (03) :256-261
[2]   Angiographic and clinical outcome following coronary stenting of small vessels - A comparison with coronary stenting of large vessels [J].
Akiyama, T ;
Moussa, I ;
Reimers, B ;
Ferraro, M ;
Kobayashi, Y ;
Blengino, S ;
Di Francesco, L ;
Finci, L ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) :1610-1618
[3]   Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts [J].
Baim, DS ;
Wahr, D ;
George, B ;
Leon, MB ;
Greenberg, J ;
Cutlip, DE ;
Kaya, U ;
Popma, JJ ;
Ho, KKL ;
Kuntz, RE .
CIRCULATION, 2002, 105 (11) :1285-1290
[4]  
DEFEYTER PJ, 1993, J ANI COLL CARDIOL, V89, P1539
[5]   COMPARATIVE RESULTS OF TRANSLUMINAL EXTRACTION CORONARY ATHERECTOMY IN SAPHENOUS-VEIN GRAFT LESIONS WITH AND WITHOUT THROMBUS [J].
DOORIS, M ;
HOFFMANN, M ;
GLAZIER, S ;
JURAN, N ;
REDDY, V ;
GRINES, CL ;
PAVLIDES, GS ;
SCHREIBER, T ;
ONEILL, WW ;
SAFIAN, RD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) :1700-1705
[6]  
DOORIS M, 2001, MANUAL INTERVENTIONA, P321
[7]   Vessel size and long-term outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Neumann, FJ ;
Hadamitzky, M ;
Dirschinger, J ;
Schömig, A .
CIRCULATION, 1998, 98 (18) :1875-1880
[8]   Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :43-49
[9]   Creatine kinase-MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality [J].
Hong, MK ;
Mehran, R ;
Dangas, G ;
Mintz, GS ;
Lansky, AJ ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Stone, GW ;
Leon, MB .
CIRCULATION, 1999, 100 (24) :2400-2405
[10]   Acute and long-term outcomes of stenting in coronary vessel &gt;3.0 mm, 3.0-2.5 mm, and &lt;2.5 mm [J].
Hsieh, IC ;
Chien, CC ;
Chang, HJ ;
Chern, MS ;
Hung, KC ;
Lin, FC ;
Wu, D .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (03) :314-322