Elimination of matrix effects for static headspace analysis of ethanol

被引:27
作者
Strassnig, S [1 ]
Lankmayr, EP [1 ]
机构
[1] Graz Tech Univ, Inst Analyt Chem Micro & Radiochem, A-8010 Graz, Austria
关键词
headspace analysis; matrix effects; regression analysis; ethanol; alcohols; albumin; proteins;
D O I
10.1016/S0021-9673(99)00611-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The intention of this work was to develop a simple and fast procedure for a determination of small amounts of ethanol in aqueous protein containing solutions based on combined headspace gas chromatography. In order to provide for short analysis time static headspace methodology was considered for this purpose. In this context the influence of the matrix composition onto the analytical results has been established and internal standardization as well as a full evaporation technique have been evaluated as promising alternatives for a compensation of matrix effects. With respect to speed of analysis, simplicity of sample handling as well as the quality of the analytical performance parameters, precision and accuracy, the full evaporation technique proved to be superior. Thus, the static equilibration of a 20 mu l sample aliquot in a conventional headspace sample vial for 5 min at 100 degrees C is sufficient to obtain equilibrium conditions for gas chromatographic analysis. The accuracy of this method was verified by robust regression analysis and exhibited excellent robustness within the required Limits of sample composition ranging from 0 to 20% (w/w) protein content and up to 5 g/l salt content. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:629 / 636
页数:8
相关论文
共 19 条
[1]  
[Anonymous], STAT HEADSPACE GAS C
[2]  
[Anonymous], 1986, ROBUST STAT
[3]  
BABLOK W, 1988, J CLIN CHEM CLIN BIO, V26, P783
[4]   Headspace gas chromatography with capillary column for urine alcohol determination [J].
Corrêa, CL ;
Pedroso, RC .
JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2) :365-368
[5]   SYSTEMATIC-ERRORS WITH THE USE OF INTERNAL STANDARD CALIBRATION IN GAS-CHROMATOGRAPHIC HEADSPACE ANALYSIS [J].
DROZD, J ;
VODAKOVA, Z ;
KOUPIL, P .
JOURNAL OF CHROMATOGRAPHY, 1990, 518 (01) :1-8
[6]  
FUNK W, 1992, QUALITATSSICHERUNG A, P26
[7]  
Glazkov VV, 1997, J ANAL CHEM+, V52, P71
[8]   Robust orthogonal regression for the outlier detection when comparing two series of measurement results [J].
Hartmann, C ;
Vankeerberghen, P ;
SmeyersVerbeke, J ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 1997, 344 (1-2) :17-28
[9]  
Hauck G., 1969, CHROMATOGRAPHIA, V2, P309
[10]  
*ISO, 1990, 84661 ISO 1