Audit of oxygen use in emergency ambulances and in a hospital emergency department

被引:70
作者
Hale, K. E. [1 ]
Gavin, C. [1 ]
O'Driscoll, B. R. [1 ]
机构
[1] Salford Royal Hosp Fdn NHS Trust, Salford, Lancs, England
关键词
D O I
10.1136/emj.2008.059287
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Oxygen is widely used but poorly studied in emergency medicine, with a limited evidence base for its use in specific conditions. There are safety concerns about the underuse of oxygen in patients with critical illness and its overuse in conditions such as chronic obstructive pulmonary disease (COPD). A baseline audit was required to assess current practice prior to the introduction of new national emergency oxygen guidelines in late 2008. Methods: The use of pulse oximetry and oxygen therapy was audited in patients brought by ambulance to the "majors'' section of the emergency department (ED) in a university hospital. Oxygen therapy in the ambulance and the ED was subsequently documented. Oxygen use in ambulances was compared with Joint Royal Colleges Ambulance Liaison Committee (JRCALC) guidance and with subsequent patient management. Results: The ambulance and ED records of 1022 patients were audited manually. Oxygen saturation (Sp(O2)) was recorded for 90% of patients, 17% of whom had Sp(O2), <94% at some time and 7% had SpO2,90%, including 33% of patients with COPD and 5.5% of patients without COPD. 34% of patients received oxygen in the ambulance and almost half of these had oxygen discontinued in the ED. Only 62% of ambulance oxygen use was in accordance with JRCALC guidance, but most "undertreated'' patients were stable normoxaemic patients for whom guidance recommends high-flow oxygen. Only 58% of patients with COPD were correctly identified in the ambulance and 73% of these patients were treated with flow rates >41/min (equivalent to >35% oxygen). Conclusions: Oxygen use in ambulances is very common, equivalent to 2.2 million episodes annually in the UK. The quality of oxygen use is suboptimal, especially for patients with COPD. Emergency oxygen therapy will become simpler when new evidence-based UK emergency oxygen guidelines are published, and it is hoped that future audits will show better protocol adherence.
引用
收藏
页码:773 / 776
页数:4
相关论文
共 21 条
[1]   VARIABILITY OF INSPIRED OXYGEN CONCENTRATION WITH NASAL CANNULAS [J].
BAZUAYE, EA ;
STONE, TN ;
CORRIS, PA ;
GIBSON, GJ .
THORAX, 1992, 47 (08) :609-611
[2]   Oxygen therapy in myocardial infarction: an historical perspective [J].
Beasley, Richard ;
Aldington, Sarah ;
Weatherall, Mark ;
Robinson, Geoffrey ;
McHaffie, David .
JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 2007, 100 (03) :130-133
[3]   THE INCIDENCE AND EFFECT ON OUTCOME OF HYPOXEMIA IN HOSPITALIZED MEDICAL PATIENTS [J].
BOWTON, DL ;
SCUDERI, PE ;
HAPONIK, EF .
AMERICAN JOURNAL OF MEDICINE, 1994, 97 (01) :38-46
[4]  
Considine Julie, 2005, Contemp Nurse, V18, P258
[5]   The use of oxygen in acute exacerbations of chronic obstructive pulmonary disease: a prospective audit of pre-hospital and hospital emergency management [J].
Denniston, AKO ;
O'Brien, C ;
Stableforth, D .
CLINICAL MEDICINE, 2002, 2 (05) :449-451
[6]  
Downs John B, 2003, Respir Care, V48, P611
[7]   Supplemental oxygen impairs detection of hypoventilation by pulse oximetry [J].
Fu, ES ;
Downs, JB ;
Schweiger, JW ;
Miguel, RV ;
Smith, RA .
CHEST, 2004, 126 (05) :1552-1558
[8]   Oxygen alert cards and controlled oxygen:: preventing emergency admissions at risk of hypercapnic acidosis receiving high inspired oxygen concentrations in ambulances and A&E departments [J].
Gooptu, B. ;
Ward, L. ;
Ansari, S. O. ;
Eraut, C. D. ;
Law, D. ;
Davison, A. G. .
EMERGENCY MEDICINE JOURNAL, 2006, 23 (08) :636-638
[9]   Ambulance paramedic activities in North Ayrshire: a five-year review [J].
Graham, Colin A. ;
Kumaravel, Manickam ;
Stevenson, James .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2003, 10 (04) :279-282
[10]   Reference values for arterial blood gases in the elderly [J].
Hardie, JA ;
Vollmer, WM ;
Buist, S ;
Ellingsen, I ;
Morkve, O .
CHEST, 2004, 125 (06) :2053-2060