Reliability of submaximal exercise tests in patients with COPD

被引:15
作者
Covey, MK [1 ]
Larson, JL [1 ]
Wirtz, S [1 ]
机构
[1] Univ Illinois, Coll Nursing, Chicago, IL 60612 USA
关键词
breathlessness; cycle ergometry; leg fatigue; lung disease : obstructive; oxygen uptake; reproducibility; ventilatory requirement;
D O I
10.1097/00005768-199909000-00005
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Submaximal constant work rate exercise tests are often used to measure the efficacy of an exercise intervention, but the reliability of these tests in patients with chronic obstructive pulmonary disease (COPD) has not been established Purpose: To examine the reproducibility of submaximal exercise responses of COPD patients compared with those of healthy elderly subjects. Methods: Sixteen COPD patients and 15 healthy subjects performed four weekly submaximal exercise tests against two different constant work rates: 20 W and 50% of the peak work rate (PWR). Spirometry was performed before each exercise test. COPD patients and healthy subjects were: age 69 +/- 5 and 65 +/- 5 yr, body mass index 26.4 +/- 3.9 and 26.7 +/- 3.0 kg.m(-2), respectively. Results: Both groups had no change in minute ventilation ((V) over dot (E)), oxygen uptake ((V) over dot O-2), breathlessness (RPB), and leg fatigue (RPLF) for either work rate over repeated measures (P > 0.05). At 50% PWR test-retest reliability coefficients for (V) over dot (E) and (V) over dot O-2 ranged from r = 0.88 to r = 0.96 for COPD patients and from r = 0.72 to r = 0.97 for healthy subjects; for RPB and RPLF test-retest reliability ranged from r = 0.76 to r = 0.89 for COPD patients and from r = 0.70 to r = 0.91 for healthy subjects. Intrasubject mean absolute differences for repeated measures of (V) over dot (E), (V) over dot O-2, RPB, or RPLF were low and there were no group differences (P > 0.05). Percent error for (V) over dot (E) and (V) over dot O-2 ranged from 6 +/- 3 to 9 +/- 7%, and for RPB and RPLF ranged from 19 +/- 18 to 68 +/- 65% for both groups at each work rare. Conclusions: Submaximal exercise responses were reliable over a 1-month period, and measures of the physiological and psychophysical responses of COPD patients were as reliable as those of healthy subjects.
引用
收藏
页码:1257 / 1264
页数:8
相关论文
共 43 条
[1]   THE MEASUREMENT OF BREATHLESSNESS INDUCED IN NORMAL SUBJECTS - VALIDITY OF 2 SCALING TECHNIQUES [J].
ADAMS, L ;
CHRONOS, N ;
LANE, R ;
GUZ, A .
CLINICAL SCIENCE, 1985, 69 (01) :7-16
[2]   EFFECTS OF PHYSICAL-TRAINING ON HEMODYNAMICS AND PULMONARY-FUNCTION AT REST AND DURING EXERCISE IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
ALPERT, JS ;
BASS, H ;
SZUCS, MM ;
BANAS, JS ;
DALEN, JE ;
DEXTER, L .
CHEST, 1974, 66 (06) :647-651
[3]  
[Anonymous], 1995, AM J RESP CRIT CARE, V152, P2185
[4]   VARIABILITY OF RESPIRATION AND METABOLISM - RESPONSES TO SUBMAXIMAL CYCLING AND RUNNING [J].
ARMSTRONG, LE ;
COSTILL, DL .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1985, 56 (02) :93-96
[5]   PSYCHO-PHYSICAL EFFECTS OF VARIED REST INTERVALS FOLLOWING WARM-UP [J].
ARONCHICK, J ;
BURKE, EJ .
RESEARCH QUARTERLY, 1977, 48 (02) :260-264
[6]   RELIABILITY AND WITHIN-SUBJECT VARIABILITY OF VE, VO2, HEART-RATE AND BLOOD-PRESSURE DURING SUBMAXIMUM CYCLE ERGOMETRY [J].
BECQUE, MD ;
KATCH, V ;
MARKS, C ;
DYER, R .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (04) :220-223
[7]   VARIABILITY OF BREATHLESSNESS MEASUREMENT IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
BELMAN, MJ ;
BROOKS, LR ;
ROSS, DJ ;
MOHSENIFAR, Z .
CHEST, 1991, 99 (03) :566-571
[8]   PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[9]  
BURROWS B, 1961, AM REV RESPIR DIS, V84, P789
[10]   Physiologic benefits of exercise training in rehabilitation of patients with severe chronic obstructive pulmonary disease [J].
Casaburi, R ;
Porszasz, J ;
Burns, MR ;
Carithers, ER ;
Chang, RSY ;
Cooper, CB .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (05) :1541-1551