Ultrapure dialysate: Facts and myths

被引:47
作者
Bommer, J
Jaber, BL
机构
[1] Univ Heidelberg, Dept Internal Med, D-6900 Heidelberg, Germany
[2] Tufts Univ, Sch Med, Dept Med, Boston, MA 02111 USA
[3] Caritas St Elizabeths Med Ctr, Dept Med, Div Nephrol, Boston, MA USA
关键词
D O I
10.1111/j.1525-139X.2006.00136.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
During hemodialysis, blood comes in contact with a large volume of dialysate. Since the purity of dialysate has been linked to acute and long-term complications in hemodialysis patients, the limit of bacterial and endotoxin contamination has been reduced in recent years. Questions have been raised as to whether ultrapure dialysate is required to prevent such complications; in particular, the chronic inflammatory status frequently found in chronically hemodialyzed patients. In vivo and in vitro data suggest that cytokine stimulation in the blood depends on the concentration of bacteria or endotoxin in the dialysate and on the endotoxin permeability of the dialysis membrane. It is not proven whether ultrapure dialysate reduces significantly proinflammatory cytokine generation compared with standard dialysate within the limits of recent recommendations, if rather impermeable dialysis membranes are used. Cuprophane membranes are more permeable to cytokine-inducing substances compared with synthetic membranes such as polysulfone and polyamide. Clinical reports have also attempted to link several acute and chronic complications of hemodialysis to dialysate purity. To date, however, there is no large randomized clinical trial demonstrating that ultrapure dialysate significantly reduces biomarkers of inflammation and other consequential putative complications, including dialysis-related amyloidosis, erythropoietin requirement, and cardiovascular morbidity and mortality. In conclusion, based on the existing clinical data, ultrapure dialysate is recommended in the setting of suboptimal bacteriologic quality of standard dialysate and the use of permeable dialysis membranes.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 33 条
[1]  
[Anonymous], KIDNEY INT S
[2]   THE EFFECTS OF ENDOTOXIN-CONTAMINATED DIALYSATE AND POLYSULFONE OR CELLULOSIC MEMBRANES ON THE RELEASE OF TNF-ALPHA DURING SIMULATED DIALYSIS [J].
ARDUINO, MJ ;
BLAND, LA ;
MCALLISTER, SK ;
FAVERO, MS .
ARTIFICIAL ORGANS, 1995, 19 (09) :880-886
[3]   USING ULTRAPURE WATER IN HEMODIALYSIS DELAYS CARPAL-TUNNEL SYNDROME [J].
BAZ, M ;
DURAND, C ;
RAGON, A ;
JABER, K ;
ANDRIEU, D ;
MERZOUK, T ;
PURGUS, R ;
OLMER, M ;
REYNIER, JP ;
BERLAND, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11) :681-685
[4]  
BLAND LA, 1995, J AM SOC NEPHROL, V5, P1634
[5]  
BOMMER J, 1987, CLIN NEPHROL, V27, P278
[6]  
Bommer J, 1996, J AM SOC NEPHROL, V7, P883
[7]   Acute inflammatory response to endotoxin in mice and humans [J].
Copeland, S ;
Warren, HS ;
Lowry, SF ;
Calvano, SE ;
Remick, D .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (01) :60-67
[8]   INVITRO STUDY OF THE TRANSFER OF CYTOKINE-INDUCING SUBSTANCES ACROSS SELECTED HIGH-FLUX HEMODIALYSIS MEMBRANES [J].
EVANS, RC ;
HOLMES, CJ .
BLOOD PURIFICATION, 1991, 9 (02) :92-101
[9]   FILTRATION OF DIALYSATE USING AN ONLINE DIALYSATE FILTER [J].
FRINAK, S ;
POLASCHEGG, HD ;
LEVIN, NW ;
POHLOD, DJ ;
DUMLER, F ;
SARAVOLATZ, LD .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11) :691-697
[10]   HEMODIALYSIS-ASSOCIATED FEBRILE EPISODES - SURVEILLANCE BEFORE AND AFTER MAJOR ALTERATION IN THE WATER-TREATMENT SYSTEM [J].
GAYNES, R ;
FRIEDMAN, C ;
MACLAREN, C ;
FOLEY, K ;
SWARTZ, R .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (08) :482-487