The effects of cellular contraction on aortic valve leaflet flexural stiffness

被引:100
作者
Merryman, WD
Huang, HYS
Schoen, FJ
Sacks, MS
机构
[1] Univ Pittsburgh, Engineered Tissue Mech Lab, Dept Bioengn, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[3] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Pathol, Cambridge, MA 02138 USA
关键词
myofibroblast; cellular contraction; leaflet stiffness;
D O I
10.1016/j.jbiomech.2004.11.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aortic valve (AV) leaflet contains a heterogeneous interstitial cell population composed predominantly of myofibroblasts, which contain both fibroblast and smooth muscle cell characteristics. The focus of the present study was to examine aortic valve interstitial cell (AVIC) contractile behavior within the intact leaflet tissue. Circumferential strips of porcine AV leaflets were mechanically tested under flexure, with the AVIC maintained in the normal, contracted, and contraction-inhibited states. Leaflets were flexed both with (WC) and against (AC) the natural leaflet curvature, both before and after the addition of 90 mM KCI to elicit cellular contraction. In addition, a natural basal tonus was also demonstrated by treating the leaflets with 10 mu M thapsigargin to completely inhibit AVIC contraction. Results revealed a 48% increase in leaflet stiffness with AVIC contraction (from 703 to 1040 kPa, respectively) when bent in the AC direction (p = 0.004), while the WC direction resulted only in 5% increase (from 491 to 516.5 kPa, respectively-not significant) in leaflet stiffness in the active state. Also, the loss of basal tonus of the AVIC population with thapsigargin treatment resulted in 76% (AC, p = 0.001) and 54% (WC, p = 0.036) decreases in leaflet stiffness at 5 mM KCI levels, while preventing contraction with the addition of 90 mM KCI as expected. We speculate that the observed layer dependent effects of AVIC contraction are primarily due to varying ECM mechanical properties in the ventricularis and fibrosa layers. Moreover, while we have demonstrated that AVIC contractile ability is a significant contributor to AV leaflet bending stiffness, it most likely serves a role in maintaining AV leaflet tissue homeostasis that has yet to be elucidated. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 30 条
[1]   PRESENCE OF A SMOOTH-MUSCLE SYSTEM IN AORTIC-VALVE LEAFLETS [J].
BAIRATI, A ;
DEBIASI, S .
ANATOMY AND EMBRYOLOGY, 1981, 161 (03) :329-340
[2]   Biaxial mechanical properties of the native and glutaraldehyde-treated aortic valve cusp: Part II - A structural constitutive model [J].
Billiar, KL ;
Sacks, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04) :327-335
[3]   Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp - Part I: Experimental results [J].
Billiar, KL ;
Sacks, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01) :23-30
[4]  
CHESTER AH, 2003, SPECIFIC REGIONAL DI
[5]   AGE-DEPENDENT CHANGES IN THE RADIAL STRETCH OF HUMAN AORTIC-VALVE LEAFLETS DETERMINED BY BIAXIAL TESTING [J].
CHRISTIE, GW ;
BARRATTBOYES, BG .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S156-S159
[6]   Cell composition of the human pulmonary valve: A comparative study with the aortic valve - The VESALIO* project [J].
Della Rocca, F ;
Sartore, S ;
Guidolin, D ;
Bertiplaglia, B ;
Gerosa, G ;
Casarotto, D ;
Pauletto, P .
ANNALS OF THORACIC SURGERY, 2000, 70 (05) :1594-1600
[7]   A novel bioreactor for the dynamic flexural stimulation of tissue engineered heart valve biomaterials [J].
Engelmayr, GC ;
Hildebrand, DK ;
Sutherland, FWH ;
Mayer, JE ;
Sacks, MS .
BIOMATERIALS, 2003, 24 (14) :2523-2532
[8]   INTERSTITIAL-CELLS OF THE HEART-VALVES POSSESS CHARACTERISTICS SIMILAR TO SMOOTH-MUSCLE CELLS [J].
FILIP, DA ;
RADU, A ;
SIMIONESCU, M .
CIRCULATION RESEARCH, 1986, 59 (03) :310-320
[9]  
Hafizi S, 2000, J HEART VALVE DIS, V9, P454