Covalent Attachment of Biomacromolecules to Plasma-Patterned and Functionalized Carbon Nanotube-Based Devices for Electrochemical Biosensing

被引:13
作者
Kim, Joon Hyub [1 ]
Jin, Joon-Hyung [2 ]
Lee, Jun-Yong [1 ]
Park, Eun Jin [3 ]
Min, Nam Ki [1 ,4 ]
机构
[1] Korea Univ, Dept Biomicrosyst Technol, Seoul 136701, South Korea
[2] Korea Univ, Dept Elect Engn, Seoul 136701, South Korea
[3] Seoul Natl Univ, Dept Phys & Astron, Seoul 151747, South Korea
[4] Korea Univ, Dept Control & Instrumentat Engn, Yeongi Gun 339700, Chungnam, South Korea
关键词
ELECTRON-TRANSFER; APTASENSOR; AMPLIFICATION; LEGIONELLA;
D O I
10.1021/bc300275z
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
The interface between biomacromolecules and carbon nanotubes (CNTs) is of critical importance in developing effective techniques that provide CNTs with both biomolecular recognition and signal transduction through immobilization. However, the chemical inertness of CNT surfaces poses an obstacle to wider implementation of CNTs in bioanalytical applications. In this paper, we present a review of our recent research activities related to the covalent attachment of biomacromolecules to plasma-patterned and functionalized carbon nanotube films and their application to the fabrication of electrochemical biosensing devices. The SWCNT films were spray-deposited onto a miniaturized three-electrode system on a glass substrate and activated using highly purified atomic oxygen generated in radiofrequency plasma; this introduced oxygen-containing functional groups into the SWCNT surface without fatal loss of the original physicochemical properties of the CNTs. The carboxylated SWCNT electrodes were then selectively modified via amidation or esterification for covalent immobilization of the biomacromolecules. The plasma-treated SWCNT-based sensing electrode had an approximately six times larger effective area than the untreated SWCNT-based electrode, which significantly amplified the amperometric electrochemical signal. Finally, the efficacy of plasma-functionalized SWCNT (pf-SWCNT) as a biointerface was examined by immobilizing glucose oxidase, Legionella pneumophila (L, pneumophila)-specific antibodies, L. pneumophila-originated DNAs, and thrombin-specific aptamers on the pf-SWCNT-based three-electrode devices. The pf-SWCNT films were found to support direct covalent immobilization of the above-listed biomacromolecules on the films and to thereby overcome the many drawbacks typically associated with simple physisorption. Thus, pf-SWCNT sensing electrodes on which biomacromolecules were covalently immobilized were found to be chemically stable and have a long lifetime.
引用
收藏
页码:2078 / 2086
页数:9
相关论文
共 20 条
[2]
Bioelectrochemical single-walled carbon nanotubes [J].
Azamian, BR ;
Davis, JJ ;
Coleman, KS ;
Bagshaw, CB ;
Green, MLH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (43) :12664-12665
[3]
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization [J].
Chen, RJ ;
Zhang, YG ;
Wang, DW ;
Dai, HJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (16) :3838-3839
[4]
Demonstration of the importance of oxygenated species at the ends of carbon nanotubes for their favourable electrochemical properties [J].
Chou, A ;
Böcking, T ;
Singh, NK ;
Gooding, JJ .
CHEMICAL COMMUNICATIONS, 2005, (07) :842-844
[5]
Functionalizing single-walled carbon nanotube networks: Effect on electrical and electrochemical properties [J].
Dumitrescu, Ioana ;
Wilson, Neil R. ;
Macpherson, Julie V. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (35) :12944-12953
[6]
Electro-chemical and biological properties of carbon nanotube based multi-electrode arrays [J].
Gabay, Tamir ;
Ben-David, Moti ;
Kalifa, Itshak ;
Sorkin, Raya ;
Abrams, Ze'ev R. ;
Ben-Jacob, Eshel ;
Hanein, Yael .
NANOTECHNOLOGY, 2007, 18 (03)
[7]
Direct electron transfer of glucose oxidase on carbon nanotubes [J].
Guiseppi-Elie, A ;
Lei, CH ;
Baughman, RH .
NANOTECHNOLOGY, 2002, 13 (05) :559-564
[8]
Ultrasensitive electrochemical detection of proteins by amplification of aptamer-nanoparticle bio bar codes [J].
He, Pingli ;
Shen, Li ;
Cao, Yunhe ;
Lia, Defa .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8024-8029
[9]
Oxygen functionalisation of MWNT and their use as gas sensitive thick-film layers [J].
Ionescu, R ;
Espinosa, EH ;
Sotter, E ;
Llobet, E ;
Vilanova, X ;
Correig, X ;
Felten, A ;
Bittencourt, C ;
Van Lier, G ;
Charlier, JC ;
Pireaux, JJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) :36-46
[10]
Effects of surface modification on rheological and mechanical properties of CNT/epoxy composites [J].
Kim, Jin Ah ;
Seong, Dong Gi ;
Kang, Tae Jin ;
Youn, Jae Ryoun .