An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film

被引:125
作者
Harris, ML
Morberg, P
Bruce, WJM
Walsh, WR [1 ]
机构
[1] Univ New S Wales, Prince Wales Hosp, Orthopaed Res Labs, Dept Orthopaed, Randwick, NSW 2031, Australia
[2] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW, Australia
[3] Univ Gothenburg, Dept Handicap Res, Biomat Grp, Gothenburg, Sweden
[4] Gothenburg Univ, Sahlgrenska Hosp, Ostra Inst Surg Sci, Dept Orthopaed, Gothenburg, Sweden
[5] Othosports, Sydney, NSW, Australia
关键词
arthroplasty; contact area; knee prosthesis; polyethylene; pressure sensitive film;
D O I
10.1016/S0021-9290(99)00072-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A computerised, real time, thin-film pressure transducer method is used to measure tibiofemoral contact area in total knee arthroplasty (TKA) devices that is easier and more reliable and reproducible as compared to the Fuji pressure-sensitive film technique. Many authors have suggested that contact areas and pressures within TKA devices can be a predictor of wear and failure of the ultra-high molecular weight polyethylene (UHMWPE) tibial insert. In this study, two contact area measurement techniques (Fuji pressure-sensitive Film and K-scan sensor system) were compared using a custom TKA testing jig designed for freedom of movement so that in any loading configuration the component found and seated in its own "home" position. The K-scan system was used to measure contact areas of one TKA design at several angles from 0 to 110 degrees flexion with loads equating to 4, 4.5, and 5 times body weight. For comparison, four ranges of Fuji film were used to measure areas at the same flexion angles but at 5 times body weight only. Contact areas measured with the Fuji films were 11-36% (p < 0.05) lower than those measured by the K-scan sensor. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 45 条
[1]   INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE [J].
AHMED, AM ;
BURKE, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :216-225
[2]   A STUDY OF LOWER-LIMB MECHANICS DURING STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
ANDERSSON, GBJ ;
FERMIER, RW ;
STERN, D ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (05) :749-757
[3]   A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124
[4]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[5]  
BLACK JD, 1981, CLIN ORTHOP RELAT R, P265
[6]   Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses [J].
Blunn, GW ;
Joshi, AB ;
Minns, RJ ;
Lidgren, L ;
Lilley, P ;
Ryd, L ;
Engelbrecht, E ;
Walker, PS .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :281-290
[7]  
BROWN T D, 1984, Journal of Orthopaedic Research, V2, P190, DOI 10.1002/jor.1100020210
[8]  
BUECHEL FF, 1991, CLIN ORTHOP RELAT R, P190
[9]  
CAPUTO AE, 1998, ORS T NEW ORLEANS, V44
[10]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, V273, P198