Comparison of (18)FDG-PET with (131)iodine and Tc-99m-sestamibi scintigraphy in differentiated thyroid cancer

被引:117
作者
Grunwald, F
Menzel, C
Bender, H
Palmedo, H
Willkomm, P
Ruhlmann, J
Franckson, T
Biersack, HJ
机构
[1] Department of Nuclear Medicine, University of Bonn
[2] Oberarzt der Klinik, Poliklinik für Nuklearmedizin, Universität Bonn, 53127 Bonn
关键词
D O I
10.1089/thy.1997.7.327
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(18)Fluorine-fluorodeoxyglucose (FDG) positron-emission tomography (PET) has emerged as a useful method in various fields of oncology. The aim of the present study was to evaluate the clinical significance of this technique in differentiated thyroid carcinoma and to compare the results with other imaging modalities, particularly with whole-body (131)iodine scintigraphy (WBS) and hexakis (2-methoxyisobutylisonitrile) (99m)technetium (I) scintigraphy (MIBI). Whole-body PET imaging using I;DG was performed in 54 patients. There were 39 patients with papillary tumors and 15 patients with follicular tumors (including 3 Hurthle-cell carcinomas). Primary tumor stage (pT) was pT1 in 5 cases, pT2 in 19 cases, pT3 in 2 cases, pT4 in 24 cases, and unknown in 4 cases, respectively. Finally, for each case an overall clinical evaluation was done including histology, cytology, thyroglobulin level, sonography, computed tomography, magnetic resonance imaging, and subsequent clinical course, to allow a comparison with functional imaging results. Compared with WBS, FDG-PET gave different results in the majority of cases with recurrence/metastases (11 FDG-true-positive/WBS-negative tumor sites and 8 WBS-true-positive/FDG-negative tumor sites). In 7 patients with recurrence/metastases, FDG-PET and WBS gave corresponding results (10 sites). In 28 patients, FDG-PET and WBS were normal (including 2 false-negative cases). MIBI was performed in 44 cases. FDG-PET was better correlated to MIBI (congruent positive results in 13 tumor sites) than to WBS. Compared with MIBI, FDG-PET was superior in 5 cases (including 3 patients with distant metastases). Two FDG-negative/MIBI-positive tumors were. observed. Different tracer uptake mechanisms have to be considered regarding ''nonspecific'' tumor imaging with FDG-PET or MIBI. Nevertheless, since spatial resolution with respect to tomographic imaging is inferior with single photon emission computer tomography (SPECT) using MTBI, the observed higher sensitivity of PET might be due to the higher spatial resolution of this method. As far as grading could be obtained, FDG-PET seemed to be more sensitive than WBS in high-grade tumors, whereas WBS was positive predominantly in low-grade carcinomas, although statistical significance could not be reached. The results prove the clinical usefulness of FDG-PET and MIBI for detection of (131)iodine-negative tumor tissue in differentiated thyroid cancer.
引用
收藏
页码:327 / 335
页数:9
相关论文
共 29 条
  • [1] AKSLEN LA, 1993, CANCER, V72, P2680, DOI 10.1002/1097-0142(19931101)72:9<2680::AID-CNCR2820720926>3.0.CO
  • [2] 2-D
  • [3] BALON HR, 1992, J NUCL MED, V33, P1393
  • [4] BAQAI FH, 1994, 68 ANN M AM THYR ASS, P9
  • [5] THE CLINICIAN AND THE THYROID
    BIERSACK, HJ
    HOTZE, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (09): : 761 - 778
  • [6] BRIELE B, 1991, NUKLEARMED, V30, P115
  • [7] Conti P. S., 1996, Journal of Nuclear Medicine, V37, p135P
  • [8] CLINICAL UTILITY OF TC-99M METHOXISOBUTYLISONITRILE IMAGING IN DIFFERENTIATED THYROID-CARCINOMA - COMPARISON WITH THALLIUM-2O1 AND I-131 NA SCINTIGRAPHY, AND SERUM THYROGLOBULIN QUANTITATION
    DADPARVAR, S
    CHEVRES, A
    TULCHINSKY, M
    KRISHNABADRINATH, L
    KHAN, AS
    SLIZOFSKI, WJ
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (11): : 1330 - 1338
  • [9] EASTON E, 1995, J NUCL MED, V36, P197
  • [10] Feine U, 1996, J NUCL MED, V37, P1468