Colonic polyps: Complementary role of computer-aided detection in CT Colonography

被引:103
作者
Summers, RM
Jerebko, AK
Franaszek, M
Malley, JD
Johnson, CD
机构
[1] NIH, Warren Grant Magnuson Clin Ctr, Dept Diagnost Radiol, Bethesda, MD 20892 USA
[2] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
关键词
colon; CT; colon neoplasms; colonoscopy; computers; diagnostic aid;
D O I
10.1148/radiol.2252011619
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To apply a computer-aided detection (CAD) algorithm to supine and prone multisection helical computed tomographic (CT) colonographic images to confirm if there is any added benefit provided by CAD over that of standard clinical interpretation. MATERIALS AND METHODS: CT colonography (with patients in both supine and prone positions) was performed with a multisection helical CT scanner in 40 asymptomatic high-risk patients. There were two consecutive series of patients, 20 of whom had at least one polyp 1.0 cm in size or larger and 20 of whom had normal colons at conventional colonoscopy performed the same day. The CT colonographic images were interpreted with an automated CAD algorithm and by two radiologists who were blinded to colonoscopy findings RESULTS: For 25 polyps at least 1.0 cm in size ("large" polyps), sensitivity for detection by at least one radiologist was 48% (12 of 25). The sensitivity of CAD for detecting large polyps was also 48% (12 of 25), but the CAD algorithm detected four of 13 large polyps that were not detected by either radiologist (31%, 95% two-sided Cl: 9, 61), increasing,the potential sensitivity to 64% (16 of 25). For polyps identifiable retrospectively, sensitivity of CAD was 67% (12 of 18), and sensitivity of the combination of detection with the CAD algorithm or by at least one radiologist was 89% (161 of 18). There were an average of 11 false-positive detections per patient for CAD. CONCLUSION: In this series, of patients in whom radiologists had difficulties detecting polyps (compared with sensitivities of 75%-90% reported in the literature), this CAD algorithm played a complementary role to conventional interpretation of CT colonographic images by detecting a number of large polyps missed by trained observers. (C) RSNA, 2002.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 26 条
[1]   CT colonography without cathartic preparation: Feasibility study [J].
Callstrom, MR ;
Johnson, CD ;
Fletcher, JG ;
Reed, JE ;
Ahlquist, DA ;
Harmsen, WS ;
Tait, K ;
Wilson, LA ;
Corcoran, KE .
RADIOLOGY, 2001, 219 (03) :693-698
[2]  
Chakraborty D. P., 2000, HDB MED IMAGING, P771
[3]   CT colonography: Value of scanning in both the supine and prone positions [J].
Chen, SC ;
Lu, DSK ;
Hecht, JR ;
Kadell, BM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :595-599
[4]   Volume rendering [J].
Drebin, Robert A. ;
Carpenter, Loren ;
Hanrahan, Pat .
Computer Graphics (ACM), 1988, 22 (04) :65-74
[5]   A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps [J].
Fenlon, HM ;
Nunes, DP ;
Schroy, PC ;
Barish, MA ;
Clarke, PD ;
Ferrucci, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (20) :1496-1503
[6]  
FENLON HM, 2000, NEW ENGL J MED, V342, P524
[7]   Optimization of CT colonography technique: Prospective trial in 180 patients [J].
Fletcher, JG ;
Johnson, CD ;
Welch, TJ ;
MacCarty, RL ;
Ahlquist, DA ;
Reed, JE ;
Harmsen, WS ;
Wilson, LA .
RADIOLOGY, 2000, 216 (03) :704-711
[8]   Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center [J].
Freer, TW ;
Ulissey, MJ .
RADIOLOGY, 2001, 220 (03) :781-786
[9]   Reducing data size and radiation dose for CT colonography [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ahlquist, DA ;
Nelson, H ;
Ehman, RL ;
Harmsen, WS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) :1181-1184
[10]  
Johnson CD, 2001, RADIOLOGY, V221, P308