Interpretation of ion flux and electron temperature profiles at the JET divertor target during high recycling and detached discharges

被引:37
作者
Monk, RD [1 ]
Loarte, A [1 ]
Chankin, A [1 ]
Clement, S [1 ]
Davies, SJ [1 ]
Ehrenberg, JK [1 ]
Guo, HY [1 ]
Lingertat, J [1 ]
Matthews, GF [1 ]
Stamp, MF [1 ]
Stangeby, PC [1 ]
机构
[1] UNIV TORONTO,INST AEROSP STUDIES,TORONTO,ON,CANADA
关键词
JET; divertor plasma; detached plasma; Langmuir probe;
D O I
10.1016/S0022-3115(97)80071-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Detailed experiments have been carried out with the JET Mark I pumped divertor to characterise high recycling and detached plasma regimes. This paper presents new measurements of high resolution divertor ion flux profiles that identify the growth of additional peaks during high recycling discharges. These ion flux profiles are used in conjunction with D alpha and neutral flux measurements to examine the physics of divertor detachment and compare against simple analytic models. Finally, problems are highlighted with conventional methods of single and triple probe interpretation under high recycling conditions. By assuming that the single probe behaves as an asymmetric double probe the whole characteristic may be fitted and significantly lower electron temperatures may be derived when the electron to ion saturation current ratio is reduced. The results from the asymmetric double probe fit are shown to be consistent with independent diagnostic measurements.
引用
收藏
页码:396 / 401
页数:6
相关论文