Adaptive reduction of heart sounds from lung sounds using fourth-order statistics

被引:61
作者
Hadjileontiadis, LJ [1 ]
Panas, SM [1 ]
机构
[1] ARISTOTELIAN UNIV THESSALONIKI,FAC TECHNOL,DEPT ELECT & COMP ENGN,GR-54006 THESSALONIKI,GREECE
关键词
adaptive; heart sounds; higher-order statistics; lung sounds;
D O I
10.1109/10.594906
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When recording lung sounds, an incessant noise source occurs due to heart sounds, This noise source severely contaminates the breath sound signal and interferes in the analysis of lung: sounds, In this paper, an adaptive heart-noise reduction method, based on fourth-order statistics (FOS) of the recorded signal, without requiring recorded ''noise-only'' reference signal, is presented, This algorithm uses adaptive filtering to preserve the entire spectrum. Furthermore, the proposed filter is independent of Gaussian uncorrelated noise and insensitive to the step-size parameter, It converges fast with small excess errors rand, due to the narrowband nature of heart noise (HN), it requires a very small number of taps. Results from experiments with healthy subjects indicate a local HN reduction equal to or greater than 90%.
引用
收藏
页码:642 / 648
页数:7
相关论文
共 12 条
[1]  
BERNE R, 1990, PRINCIPLES PHYSL 4, P214
[2]  
Gavriely N., 1981, Journal of Applied Physiology, V50, P320
[3]  
GUYTON AC, 1991, TXB MED PHYSL, P255
[4]   REDUCTION OF HEART SOUNDS FROM LUNG SOUNDS BY ADAPTIVE FILTERING [J].
IYER, VK ;
RAMAMOORTHY, PA ;
HONG, F ;
PLOYSONGSANG, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1141-1148
[5]  
KOMPIS M, 1992, P ANN INT C IEEE, V2, P691
[6]  
Lu Y. S., 1988, P IEEE ENG MED BIOL, V1, P175
[7]  
NIKIAS CL, 1993, IEEE SIGNAL PROC JUL, P10
[8]  
NIKIAS CL, 1993, PR HALL SIG, P1
[9]  
PLOYSONGSANG Y, 1989, AM REV RESPIR DIS, P951
[10]  
Rosenblatt M, 1983, HDB STATISTICS, V3, P369