Evaluation of Automatic Measurement of the Intracranial Volume Based on Quantitative MR Imaging

被引:53
作者
Ambarki, K. [1 ,2 ]
Lindqvist, T. [1 ]
Wahlin, A. [1 ,2 ]
Petterson, E. [4 ]
Warntjes, M. J. B. [4 ,5 ]
Birgander, R. [1 ]
Malm, J. [3 ]
Eklund, A. [1 ,2 ]
机构
[1] Umea Univ, Dept Radiat Sci, Umea, Sweden
[2] Umea Univ, Ctr Biomed Engn & Phys, Umea, Sweden
[3] Umea Univ, Dept Clin Neurosci, Umea, Sweden
[4] SyntheticMR ABE, Linkoping, Sweden
[5] Linkoping Univ, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
HEAD SIZE; BRAIN; ATROPHY; RELIABILITY; DISEASE;
D O I
10.3174/ajnr.A3067
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND AND PURPOSE: Brain size is commonly described in relation to ICV, whereby accurate assessment of this quantity is fundamental. Recently, an optimized MR sequence (QRAPMASTER) was developed for simultaneous quantification of T1, T2, and proton density. ICV can be measured automatically within minutes from QRAPMASTER outputs and a dedicated software, SyMRI. Automatic estimations of ICV were evaluated against the manual segmentation. MATERIALS AND METHODS: In 19 healthy subjects, manual segmentation of ICV was performed by 2 neuroradiologists (Obs1, Obs2) by using QBrain software and conventional T2-weighted images. The automatic segmentation from the QRAPMASTER output was performed by using SyMRI. Manual corrections of the automatic segmentation were performed (corrected-automatic) by Obs1 and Obs2, who were blinded from each other. Finally, the repeatability of the automatic method was evaluated in 6 additional healthy subjects, each having 6 repeated QRAPMASTER scans. The time required to measure ICV was recorded. RESULTS: No significant difference was found between reference and automatic (and corrected-automatic) ICV (P > .25). The mean difference between the reference and automatic measurement was -4.84 +/- 19.57 mL (or 0.31 +/- 1.35%). Mean differences between the reference and the corrected-automatic measurements were -0.47 +/- 17.95 mL (-0.01 +/- 1.24%) and -1.26 +/- 17.68 mL (-0.06 +/- 1.22%) for Obs1 and Obs2, respectively. The repeatability errors of the automatic and the corrected-automatic method were <1%. The automatic method required 1 minute 11 seconds (SD = 12 seconds) of processing. Adding manual corrections required another 1 minute 32 seconds (SD = 38 seconds). CONCLUSIONS: Automatic and corrected-automatic quantification of ICV showed good agreement with the reference method. SyMRI software provided a fast and reproducible measure of ICV.
引用
收藏
页码:1951 / 1956
页数:6
相关论文
共 23 条
[1]
MR Imaging of Brain Volumes: Evaluation of a Fully Automatic Software [J].
Ambarki, K. ;
Wahlin, A. ;
Birgander, R. ;
Eklund, A. ;
Malm, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (02) :408-412
[2]
Brain Ventricular Size in Healthy Elderly: Comparison Between Evans Index and Volume Measurement [J].
Ambarki, Khalid ;
Israelsson, Hanna ;
Wahlin, Anders ;
Birgander, Richard ;
Eklund, Anders ;
Malm, Jan .
NEUROSURGERY, 2010, 67 (01) :94-99
[3]
Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[4]
Head size, age and gender adjustment in MRI studies: a necessary nuisance? [J].
Barnes, Josephine ;
Ridgway, Gerard R. ;
Bartlett, Jonathan ;
Henley, Susie M. D. ;
Lehmann, Manja ;
Hobbs, Nicola ;
Clarkson, Matthew J. ;
MacManus, David G. ;
Ourselin, Sebastien ;
Fox, Nick C. .
NEUROIMAGE, 2010, 53 (04) :1244-1255
[5]
Fully-Automated Quantification of Regional Brain Volumes for Improved Detection of Focal Atrophy in Alzheimer Disease [J].
Brewer, J. B. ;
Magda, S. ;
Airriess, C. ;
Smith, M. E. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (03) :578-580
[6]
A unified approach for morphometric and functional data analysis in young, old, and demented adults using automated atlas-based head size normalization: reliability and validation against manual measurement of total intracranial volume [J].
Buckner, RL ;
Head, D ;
Parker, J ;
Fotenos, AF ;
Marcus, D ;
Morris, JC ;
Snyder, AZ .
NEUROIMAGE, 2004, 23 (02) :724-738
[7]
Temporoparietal MR Imaging Measures of Atrophy in Subjects with Mild Cognitive Impairment That Predict Subsequent Diagnosis of Alzheimer Disease [J].
Desikan, R. S. ;
Cabral, H. J. ;
Fischl, B. ;
Guttmann, C. R. G. ;
Blacker, D. ;
Hyman, B. T. ;
Albert, M. S. ;
Killiany, R. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (03) :532-538
[8]
Mini-Mental State Examination Is Sensitive to Brain Atrophy in Alzheimer's Disease [J].
Fjell, A. M. ;
Amlien, I. K. ;
Westlye, L. T. ;
Walhovd, K. B. .
DEMENTIA AND GERIATRIC COGNITIVE DISORDERS, 2009, 28 (03) :252-258
[9]
Predicting MCI outcome with clinically available MRI and CSF biomarkers [J].
Heister, D. ;
Brewer, J. B. ;
Magda, S. ;
Blennow, K. ;
McEvoy, L. K. .
NEUROLOGY, 2011, 77 (17) :1619-1628
[10]
Hippocampal atrophy rates in Alzheimer disease Added value over whole brain volume measures [J].
Henneman, W. J. P. ;
Sluimer, J. D. ;
Barnes, J. ;
van der Flier, W. M. ;
Sluimer, I. C. ;
Fox, N. C. ;
Scheltens, P. ;
Vrenken, H. ;
Barkhof, F. .
NEUROLOGY, 2009, 72 (11) :999-1007