Learning curves and reliability measures for virtual reality simulation in the performance assessment of carotid angiography

被引:109
作者
Patel, AD [1 ]
Gallagher, AG [1 ]
Nicholson, WJ [1 ]
Cates, CU [1 ]
机构
[1] Emory Univ, Sch Med, EAST, Dept Med,Div Cardiol, Atlanta, GA 30322 USA
关键词
D O I
10.1016/j.jacc.2005.12.053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Improvement in performance as measured by metric-based procedural errors must be demonstrated if virtual reality (VR) simulation is to be used as a valid means of proficiency assessment and improvement in procedural-based medical skills. BACKGROUND The Food and Drug Administration requires completion of VR simulation training for physicians learning to perform carotid stenting. METHODS Interventional cardiologists (n = 20) participating in the Emory NeuroAnatomy Carotid Training program underwent an instructional course on carotid angiography and then performed five serial simulated carotid angiograms on the Vascular Interventional System Trainer (VIST) VR simulator (Mentice AB, Gothenburg, Sweden). Of the subjects, 90% completed the full assessment. Procedure time (PT), fluoroscopy time (IT), contrast volume, and composite catheter handling errors (CE) were recorded by the simulator. RESULTS An improvement was noted in PT, contrast volume, IT, and CE when comparing the subjects' first and last simulations (all p < 0.05). The internal consistency of the VIST VR simulator as assessed with standardized coefficient alpha was high (range 0.81 to 0.93), except for FT (alpha = 0.36). Test-retest reliability was high for CE (r = 0.9, p = 0.0001). CONCLUSIONS A learning curve with improved performance was demonstrated on the VIST simulator. This study represents the largest collection of such data to date in carotid VR simulation and is the first report to establish the internal consistency of the VIST simulator and its test-retest reliability across several metrics. These metrics are fundamental benchmarks in the validation of any measurement device. Composite catheter handling errors represent measurable dynamic metrics with high test-retest rebability that are required for the high-stakes assessment of procedural skills.
引用
收藏
页码:1796 / 1802
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 1995, COGNITIVE PSYCHOL
[2]  
CATES C, 2005, CATHETER CARDIOVASC, V65, P102
[3]   Experienced laparoscopic surgeons are automated to the "fulcrum effect": An ergonomic demonstration [J].
Crothers, IR ;
Gallagher, AG ;
McClure, N ;
James, DTD ;
McGuigan, J .
ENDOSCOPY, 1999, 31 (05) :365-369
[4]  
Gallagher AG, 2005, J AM COLL CARDIOL, V45, p337A
[5]   Virtual reality training for the operating room and cardiac catheterisation laboratory [J].
Gallagher, AG ;
Cates, CU .
LANCET, 2004, 364 (9444) :1538-1540
[6]   Approval of virtual reality training for carotid stenting - What this means for procedural-based medicine [J].
Gallagher, AG ;
Cates, CU .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (24) :3024-3026
[7]   An ergonomic analysis of the fulcrum effect in the acquisition of endoscopic skills [J].
Gallagher, AG ;
McClure, N ;
McGuigan, J ;
Ritchie, K ;
Sheehy, NP .
ENDOSCOPY, 1998, 30 (07) :617-620
[8]  
Gallagher Anthony G, 2003, Semin Laparosc Surg, V10, P127, DOI 10.1177/107155170301000306
[9]   Randomized clinical trial of virtual reality simulation for laparoscopic skills training [J].
Grantcharov, TP ;
Kristiansen, VB ;
Bendix, J ;
Bardram, L ;
Rosenberg, J ;
Funch-Jensen, P .
BRITISH JOURNAL OF SURGERY, 2004, 91 (02) :146-150
[10]   Incorporation of a computerized human patient simulator in critical care training: A preliminary report [J].
Hammond, J ;
Bermann, M ;
Chen, B ;
Kushins, L .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (06) :1064-1067