Sources of variability in the determination of micronuclei in irradiated peripheral blood lymphocytes

被引:10
作者
Brown, JK
Williams, A
Withers, HR
Ow, KT
Gramacho, C
Grey, R
Amies, C
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT RADIAT ONCOL,LOS ANGELES,CA 90024
[2] PRINCE WALES HOSP,CHILDRENS LEUKEMIA CANC RES CTR,RANDWICK,NSW 2031,AUSTRALIA
关键词
micronucleus; human lymphocyte; irradiation; variability;
D O I
10.1016/S1383-5718(96)00127-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Following a dose of 4 Gy 250 kVp X-rays to the blood lymphocytes from three healthy donors the frequency of micronuclei was enumerated by three scorers. Eight slides were prepared from each blood sample with 1000 cytokinesis-blocked binucleate cells being scored for micronuclei and a recount undertaken 3 weeks later. Seven possible sources of variation were investigated: differences between donors, scorers, the four stages of sample preparation and time. A complete factorial analysis indicated that the major sources of variation were differences between donors and differences between scorers. One scorer identified fewer micronuclei than did the other two scorers in all slides of the irradiated blood samples and gave wide and inconsistent results for baseline counts. These results suggest that the performance of scorers should be screened before undertaking analysis of micronuclei. The most striking result, however, was the consistent performance of the scorers on the repeat counts compared with the very large differences between the scorers.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 26 条
[1]   MICRONUCLEI - ORIGINS, APPLICATIONS AND METHODOLOGIES - A WORKSHOP SPONSORED BY THE HEALTH-AND-SAFETY-EXECUTIVE HELD IN MANCHESTER, MAY 23-25, 1988 [J].
ARLETT, CF ;
ASHBY, J ;
FIELDER, RJ ;
SCOTT, D .
MUTAGENESIS, 1989, 4 (06) :482-485
[2]   SLIDE PREPARATION AND SAMPLING AS A MAJOR SOURCE OF VARIABILITY IN THE MOUSE MICRONUCLEUS ASSAY [J].
ASHBY, J ;
MOHAMMED, R .
MUTATION RESEARCH, 1986, 164 (04) :217-235
[3]   X-RAY INDUCTION OF MICRONUCLEI IN HUMAN LYMPHOCYTE SUBPOPULATIONS DIFFERENTIATED BY IMMUNOPEROXIDASE STAINING [J].
BAN, S ;
COLOGNE, JB .
RADIATION RESEARCH, 1992, 131 (01) :60-65
[4]  
BAUCHINGER M, 1989, CHROMOSOMAL ABERRATI, P202
[5]   SPONTANEOUS AND INDUCED MICRONUCLEI AND UDS IN PERIPHERAL LYMPHOCYTES [J].
BENDER, MA ;
SETLOW, RB .
MUTATION RESEARCH-ENVIRONMENTAL MUTAGENESIS AND RELATED SUBJECTS, 1994, 313 (2-3) :209-214
[6]   INTERINDIVIDUAL DIFFERENCES IN RADIATION RESPONSE SHOWN BY AN INVITRO MICRONUCLEUS ASSAY - EFFECTS OF 3-AMINOBENZAMIDE ON X-RAY TREATMENT [J].
CATENA, C ;
CONTI, D ;
DELNERO, A ;
RIGHI, E .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1992, 62 (06) :687-694
[7]  
DIGIORGIO C, 1994, CARCINOGENESIS, V15, P313
[8]   CYTOKINESIS-BLOCK MICRONUCLEUS METHOD IN HUMAN-LYMPHOCYTES - EFFECT OF INVIVO AGING AND LOW-DOSE X-IRRADIATION [J].
FENECH, M ;
MORLEY, AA .
MUTATION RESEARCH, 1986, 161 (02) :193-198
[9]   MEASUREMENT OF MICRONUCLEI IN LYMPHOCYTES [J].
FENECH, M ;
MORLEY, AA .
MUTATION RESEARCH, 1985, 147 (1-2) :29-36
[10]  
GANGULY BB, 1993, MUTAT RES, V295, P135